-51-
Optical Adjustment
3. Contrast adjustment
1
Select the internal test pattern signal “All black” from the projector’s menu “Menu -> Setting -> Test pattern”.
2
Loosen 2 screws
A
on the glass holders for G-panel.
3
Turn the lever
B
of polarized glass to obtain the darkest brightness and proper black color uniformity on the
screen.
4
Turn the lever
c
of optical filter to obtain the darkest brightness and proper black color uniformity on the screen.
5
Tighten the screws
A
to fix the glass holder.
Repeat steps 2 to 5 for remaining R and B contrast adjustment.
This adjustment should be taken in order of G-panel, R-panel and B-panel.
This adjustment should be taken in the dark room to adjust precisely.
Lever B
(Polarized glass)
Lever c
(optical filer)
Blue
red
Green
A
A
A
A
A
A