-3-
Safety Instructions
WARNING:
The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side
of the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is
identified with the line (
) in the schematic diagram. For continued product safety and protection of per-
sonnel injury, servicing should be made with qualified personnel.
The following precautions must be observed.
Safety Precautions
1: An isolation transformer should be connected in
the power line between the projector and the AC
line before any service is performed on the projec-
tor.
: Comply with all caution and safety-related notes
provided on the cabinet back, cabinet bottom, inside
the cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always
be certain that all the protective devices are
installed properly, such as, control knobs, adjust-
ment covers or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND PR
OPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray
parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe
to operate without danger of electric shock.
Service Personnel Warning
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always
turn off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages (15kV - 5kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
Product Safety Notice
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
!
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there
parts must be made by exactly the same parts.
Summary of Contents for PLC-XM100
Page 89: ... 89 74LVC14 Inverter IC5502 IC Block Diagrams AD8183 Analog SW IC2001 ...
Page 91: ... 91 IC Block Diagrams BA7078 Sync Separator IC1011 CXA7009 S H IC501 IC531 IC561 ...
Page 92: ... 92 IC Block Diagrams CXD3540 Digital Gamma Correction IC401 FA5502 P F Control IC601 ...
Page 93: ... 93 IC Block Diagrams ISL98001 A D Converter IC2201 M62393 DAC IC7801 ...
Page 94: ... 94 IC Block Diagrams NJM2671 Motor Controller IC5541 NJW1156 Audio Selector IC5001 ...
Page 95: ... 95 IC Block Diagrams PIC18F67 PIC IC8801 PW392 Scaler IC301 ...
Page 96: ... 96 IC Block Diagrams PW610 Keystone IC2301 STR A6079 Power switching IC603 ...
Page 97: ... 97 IC Block Diagrams TE7783 I O Expander IC4801 STR Z2156 Power switching IC651 ...
Page 98: ... 98 IC Block Diagrams THS7347 3 CH Analog SW IC5231 IC5271 TPA3123 Audio Output IC001 ...