-5-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
19
DIMMER_LEVEL_AUTO
Current Y Level (Read only)
-
-
20
DIMMER_LEVEL_NORMAL
Dim Level at Normal
0 - 15
15
21
DIMMER_LEVEL_ECO
Dim Level at Eco
0 - 15
0
23
VOLTAGE_LEVEL
Lamp Voltage (Read only)
-
-
220
Projector Error Log
0
Warning_Log_1
Latest Error log
0 - 32767
0
:
:
:
:
:
49
Warning_Log_50
50th Error log
0 - 32767
0
50
Warning_Log Reset
Log is cleared when the value is set to 10.
0 ~ 10
0
235
Shutter
0
PRE_MOTION
Shutter Warm - up Operation (0: Yes, 1: No)
0 - 1
Initial: 1 / Shipping: 0
1
CMP_TRM
Chattering Detecting Term
0 - 32767
7000
2
OUT_DLY_TRM
Output Term
0 - 32767
15000
3
CMP_CHK_CNT
Count of Information Sync
0 - 15
10
4
OPEN_DLY
Open Output Delay
0 - 63
0
5
CLOSE_DLY
Close Output Delay
0 - 63
0
6
Position Check Time
Position Check Time
1 - 255
50
8
Enable Close Cmd
Shutter Close Command 0: Disable, 1: Enable
0 - 1
1
9
Speed Control
Shutter Speed
0 - 255
0
240
Flow Calibration
0
Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1
0
* Wind sensor calibra-
tion.
1
Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
-
255
2
Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
3
Air Inlet Check Enable
Air inlet Error Detection by Wind Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
4
Time Limit Auto Scroll Enble
Auto Scroll (0: Disable, 1: Enable)
0 - 1
1
5
Clog Auto Cooling Enable
Auto Cooling at Clog (0: Disable, 1: Enable)
0 - 1
1
6
Scroll Fail Auto Cooling Enable
Auto Cooling at Scroll Error (0: Disable, 1: Enable)
0 - 1
1
241
Flow Ideal Data
(Value will be set after calibration)
0
Flow Ideal Data 1
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
0 - 1023
263
1
Flow Ideal Data 2
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
0 - 1023
263
2
Flow Ideal Data 3
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
0 - 1023
308
3
Flow Ideal Data 4
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
0 - 1023
328
4
Flow Ideal Data 5
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
0 - 1023
346
5
Flow Ideal Data 6
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
0 - 1023
361
6
Flow Ideal Data 7
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
0 - 1023
371
7
Flow Ideal Data 8
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
0 - 1023
383
242
Flow Calib. Fan Volt
(Not Memorized)
0
Flow Calib Fan Volt 1
Flow Sensor Calibration Fan Voltage No.1 [x10 V]
0 - 255
42
1
Flow Calib Fan Volt 2
Flow Sensor Calibration Fan Voltage No.2 [x10 V]
0 - 255
50
2
Flow Calib Fan Volt 3
Flow Sensor Calibration Fan Voltage No.3 [x10 V]
0 - 255
60
3
Flow Calib Fan Volt 4
Flow Sensor Calibration Fan Voltage No.4 [x10 V]
0 - 255
75
4
Flow Calib Fan Volt 5
Flow Sensor Calibration Fan Voltage No.5 [x10 V]
0 - 255
90
5
Flow Calib Fan Volt 6
Flow Sensor Calibration Fan Voltage No.6 [x10 V]
0 - 255
105
6
Flow Calib Fan Volt 7
Flow Sensor Calibration Fan Voltage No.7 [x10 V]
0 - 255
120
7
Flow Calib Fan Volt 8
Flow Sensor Calibration Fan Voltage No.8 [x10 V]
0 - 255
138
243
Flow Calib Effective Difference
(Not Memorized)
0
Flow Calib Effective Diff 1
Flow Sensor Calibration Range Diff No.1 [ADC]
0 - 1023
300
1
Flow Calib Effective Diff 2
Flow Sensor Calibration Range Diff No.2 [ADC]
0 - 1023
300
2
Flow Calib Effective Diff 3
Flow Sensor Calibration Range Diff No.3 [ADC]
0 - 1023
300
3
Flow Calib Effective Diff 4
Flow Sensor Calibration Range Diff No.4 [ADC]
0 - 1023
300
4
Flow Calib Effective Diff 5
Flow Sensor Calibration Range Diff No.5 [ADC]
0 - 1023
300
5
Flow Calib Effective Diff 6
Flow Sensor Calibration Range Diff No.6 [ADC]
0 - 1023
300
6
Flow Calib Effective Diff 7
Flow Sensor Calibration Range Diff No.7 [ADC]
0 - 1023
300
7
Flow Calib Effective Diff 8
Flow Sensor Calibration Range Diff No.8 [ADC]
0 - 1023
300
244
Flow Clog Threshold
(Not Memorized )
0
Flow Clog Threshold 1
Flow Sensor Clogged Threshold No.1[ADC]
0 - 1023
60
Summary of Contents for PLC-XM100
Page 89: ... 89 74LVC14 Inverter IC5502 IC Block Diagrams AD8183 Analog SW IC2001 ...
Page 91: ... 91 IC Block Diagrams BA7078 Sync Separator IC1011 CXA7009 S H IC501 IC531 IC561 ...
Page 92: ... 92 IC Block Diagrams CXD3540 Digital Gamma Correction IC401 FA5502 P F Control IC601 ...
Page 93: ... 93 IC Block Diagrams ISL98001 A D Converter IC2201 M62393 DAC IC7801 ...
Page 94: ... 94 IC Block Diagrams NJM2671 Motor Controller IC5541 NJW1156 Audio Selector IC5001 ...
Page 95: ... 95 IC Block Diagrams PIC18F67 PIC IC8801 PW392 Scaler IC301 ...
Page 96: ... 96 IC Block Diagrams PW610 Keystone IC2301 STR A6079 Power switching IC603 ...
Page 97: ... 97 IC Block Diagrams TE7783 I O Expander IC4801 STR Z2156 Power switching IC651 ...
Page 98: ... 98 IC Block Diagrams THS7347 3 CH Analog SW IC5231 IC5271 TPA3123 Audio Output IC001 ...
Page 152: ... KA8AL Nov 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...