Lamp Replacement
How to check Lamp used time
The LAMP REPLACE indicator will light yellow when the
total lamp used time (Corresponding value) reaches 3,000
hours. This is to indicate that lamp replacement is required.
The total lamp used time is calculated by using the below
expression,
Total lamp used time =
t
t
high x 1.5
t
normal: used time in the Normal mode
t
high : used time in the High mode and Auto mode.
You can check the lamp used time following to the below
procedure.
1
Press and hold the
oN/StANd-BY
button on the remote
control unit for more than 0 seconds.
2
The projector used time and lamp used time will be dis-
played on the screen briefly as follows.
Lamp replacement
WArNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can shatter
and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord.
2
Loosen 1 screw with a screwdriver and remove the lamp cover.
3
Loosen 3 screws and pull out the lamp assembly by grasping the ledges.
4
Replace the lamp with a new one and tighten the 3 screws back into posi-
tion. Make sure that the lamp is set properly. Replace the lamp cover and
tighten the screw.
5
Connect the AC cord to the projector and turn on.
6
Reset the lamp replacement counter, see below explanation.
Note
- The projector cannot be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also released to
switch off the lamp circuit.
How to reset Lamp replace counter
1
Turn the projector on, press the
MeNu
button and the
On-Screen Menu will appear. Press the
7
or
8
button
to
move the red frame pointer to the Setting Menu icon.
2
Press the
d
button
to move the red frame pointer to the
Lamp counter reset item and then press the
SeLect
but-
ton. Select "Reset" and press the
SeLect
button. The mes-
sage "Lamp replace counter Reset?" is displayed. Move
the pointer to [Yes] and then press the
SeLect
button.
* Refer to owner's manual for further information.
recommendation
Should the air filter become clogged with dust particles, it
will reduce the cooling fan’s effectiveness and may result in
internal heat build up and short lamp life. We recommend
cleaning the air filter after the projection lamp is replaced.
Refer to “Air Filter Cleaning”.
Lamp
Lamp Cover
Screw
Screw
Screw
Counter
Projector
525H
Lamp
High 150H
Normal 375H
Corresponding value 600H
Total lamp used time
Projector used time
order rePLAceMeNt LAMP
Type No.
Service Parts No.
POA-LMP107
610 330 4564
WArNING : turN oFF tHe uV LAMP BeFore oPeNING tHe LAMP coVer.
uSe uV rAdIAtIoN eYe ANd SKIN ProtectIoN durING SerVIcING.
Screw
Summary of Contents for PLC-XE32
Page 18: ... 18 Optical Parts Disassembly m Optical Unit Top removal M3x8 x5 Optical top Fig 7 ...
Page 53: ... 53 IC Block Diagrams FA5502 P F Control IC621 L3E6100D D A S H LCD Driver IC501 IC531 IC561 ...
Page 54: ... 54 IC Block Diagrams L3E07072 LCD Driver Gamma Correction IC401 M62393 DAC IC3531 ...
Page 55: ... 55 IC Block Diagrams NJW1141 Audio Control IC5001 ...
Page 81: ...LE7 XE3200 81 Memo ...
Page 82: ...LE7 XE3200 82 Memo ...
Page 83: ...LE7 XE3200 83 Memo ...
Page 84: ... LE7AC Jan 2008 DC 220 Printed in Japan SANYO Electric Co Ltd ...