-8-
Electrical Adjustments
[Adjustment Condition]
●
Input signal
Video signal ....................... 1.0Vp-p/75
W
terminated, 16 steps gray scale
(Composite video signal)
Component Video signal ...... 1.0Vp-p/75
W
terminated, 8 color 100% color
bar or 16 step gray scale (Component video
signal)
Computer signal ................... 0.7Vp-p/75
W
terminated, 16 steps gray scale
pattern
●
Image control mode ......... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering the
service mode and adjusting the service data.
White 100%
Black 100%
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the following
adjustments except requiring the readjustments in servicing otherwise it may cause loss of performance
and product safety. Before adjustment, please turn on the projector more than ten minutes.
16 steps gray scale pattern
After replacing the Power Board readjust the Output
voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6d
.
. Adjust the voltage by using VR611 as following.
AC Input
Reading
30V
380V ±V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
* This adjustment is not required even if the power
board is replaced because this adjustment is carried
out before parts shipment.
Output Voltage adjustment
WARNING : USE UV RAdIAtIoN EYE ANd SKIN
PRotECtIoN dURING SERVICING.
CAUtIoN:
to prevent suffer of UV radiation, those adjustments
must be completed within 25 minutes.
1. Enter the service mode.
. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”, item
no. “
0
” and change data value to adjust voltage to be
5.0 ±0.1V
.
3. Connect a digital voltmeter to test point “
tPFANB
”
(+) and chassis ground (-). Select group no. “
250
”,item
no. “
2
” and change data value to adjust voltage to be
6.2 ±0.1V
.
4. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
1
” and change data value to adjust voltage to be
13.5 ±0.1V
.
5. Connect a digital voltmeter to test point “
tPFANB
”
(+) and chassis ground (-). Select group no. “
250
”,item
no. “
3
” and change data value to adjust voltage to be
13.5 ±0.1V
.
1.Fan Control adjustment
8 color 100% color bar
W
Y
C
G
M
R
B
BLK
White 100%
Black 100%
Summary of Contents for PLC-WXE46
Page 62: ... 62 IC Block Diagrams MP2106 DC DC Converter IC5821 IC5861 FA5502 P F Control IC621 ...
Page 64: ... 64 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 NJW1156 Audio Control IC5001 ...
Page 66: ... 66 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 67: ... 67 XR16L5701IL24 UART IC9885 IC Block Diagrams ...
Page 92: ... KM5AY KM5AZ September 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 104: ...A10 SCH_KM5AY SCH_KM5AZ NO DATA ...