-64-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
236
Lamp changer
* Mirror adjustment
0
Mirror Adjust Mode
0: Normal, 1: Lamp1 Adj, 2: Lamp2 Adj.
0 - 2
0
1
Lamp Mode Lamp1
Lamp1 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
-
-
2
Lamp Mode Lamp2
Lamp2 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
-
-
10
Lamp1/Lamp2 Change Time
Sets Lamp CHange Time (unit: hour)
0 - 255
10
20
Lamp Timer On/Off
Lamp Timer 0: On, 1: Off
0 - 2
0
21
Lamp Timer Start
Starting Time Set (h)
0 - 24
0
22
Lamp Timer Conut
Timer Count Set (h)
-
23
Lamp Timer Interval
Interval (h)
1 - 255
24
24
Lamp Timer Store
Timer Store
0: Timer Clear after Power Off
1: Memorized
0 - 1
0
240
Flow Calibration
0
Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1
0
* Wind sensor
calibration.
1
Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
-
255
2
Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
3
Air Inlet Check Enable
Intake Error Detection vy Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
241
Flow Ideal Data
(Value will be set after calibration)
0
Flow Ideal Data 1
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
0 - 1023
242
1
Flow Ideal Data 2
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
0 - 1023
275
2
Flow Ideal Data 3
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
0 - 1023
309
3
Flow Ideal Data 4
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
0 - 1023
335
4
Flow Ideal Data 5
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
0 - 1023
359
5
Flow Ideal Data 6
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
0 - 1023
378
6
Flow Ideal Data 7
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
0 - 1023
428
7
Flow Ideal Data 8
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
0 - 1023
447
242
Flow Calib. Fan Duty
(Not Memorized)
0
Flow Calib Fan Duty 1
Flow Sensor Calibration Duty No.1 [%]
0 - 100
31
1
Flow Calib Fan Duty 2
Flow Sensor Calibration Duty No.2 [%]
0 - 100
36
2
Flow Calib Fan Duty 3
Flow Sensor Calibration Duty No.3 [%]
0 - 100
42
3
Flow Calib Fan Duty 4
Flow Sensor Calibration Duty No.4 [%]
0 - 100
48
4
Flow Calib Fan Duty 5
Flow Sensor Calibration Duty No.5 [%]
0 - 100
54
5
Flow Calib Fan Duty 6
Flow Sensor Calibration Duty No.6 [%]
0 - 100
60
6
Flow Calib Fan Duty 7
Flow Sensor Calibration Duty No.7 [%]
0 - 100
80
7
Flow Calib Fan Duty 8
Flow Sensor Calibration Duty No.8 [%]
0 - 100
100
243
Flow Calib Effective Difference
(Not Memorized)
0
Flow Calib Effective Diff 1
Flow Sensor Calibration Range Diff No.1 [ADC]
0 - 1023
250
1
Flow Calib Effective Diff 2
Flow Sensor Calibration Range Diff No.2 [ADC]
0 - 1023
250
2
Flow Calib Effective Diff 3
Flow Sensor Calibration Range Diff No.3 [ADC]
0 - 1023
250
3
Flow Calib Effective Diff 4
Flow Sensor Calibration Range Diff No.4 [ADC]
0 - 1023
250
4
Flow Calib Effective Diff 5
Flow Sensor Calibration Range Diff No.5 [ADC]
0 - 1023
250
5
Flow Calib Effective Diff 6
Flow Sensor Calibration Range Diff No.6 [ADC]
0 - 1023
250
6
Flow Calib Effective Diff 7
Flow Sensor Calibration Range Diff No.7 [ADC]
0 - 1023
250
7
Flow Calib Effective Diff 8
Flow Sensor Calibration Range Diff No.8 [ADC]
0 - 1023
250
244
Flow Clog Threshold
(Not Memorized )
0
Flow Clog Threshold 1
Flow Sensor Clogged Threshold No.1[ADC]
0 - 1023
36
1
Flow Clog Threshold 2
Flow Sensor Clogged Threshold No.2[ADC]
0 - 1023
57
2
Flow Clog Threshold 3
Flow Sensor Clogged Threshold No.3[ADC]
0 - 1023
75
3
Flow Clog Threshold 4
Flow Sensor Clogged Threshold No.4[ADC]
0 - 1023
92
4
Flow Clog Threshold 5
Flow Sensor Clogged Threshold No.5[ADC]
0 - 1023
108
5
Flow Clog Threshold 6
Flow Sensor Clogged Threshold No.6[ADC]
0 - 1023
121
6
Flow Clog Threshold 7
Flow Sensor Clogged Threshold No.7[ADC]
0 - 1023
153
Summary of Contents for PLC-WTC500AL
Page 102: ... 102 IC Block Diagrams NJW1141 Audio Selector IC5111 L3E07111 LCD DRIVE DIGITAL GAMMA IC401 ...
Page 103: ... 103 IC Block Diagrams M62393 DAC IC7971 NJM2671 Motor Controller IC7601 ...
Page 104: ... 104 IC Block Diagrams LC87F2G08A MCU IC4501 PW392 Scaler IC301 ...
Page 105: ... 105 IC Block Diagrams PW610 Keystone IC2301 TE7783 I O Expander IC4801 ...
Page 106: ... 106 IC Block Diagrams TPA3123 Audio Output IC5051 ...
Page 162: ... KV5AM Dec 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 174: ...A12 SCH_KV5AM NO DATA ...