-68-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
40
Eco Fan4 Min (LAMP1)
0000-9990
3640
2504
3640
3640
41
Eco Fan4 Max (LAMP1)
0000-9990
3640
2504
4040
4040
42
Eco Fan5 Min (LAMP1)
0000-9990
2504
3640
2504
2504
43
Eco Fan5 Max (LAMP1)
0000-9990
2504
3640
2904
2904
44
Eco Fan6 Min
0000-9990
2352
2352
2352
2352
45
Eco Fan6 Max
0000-9990
4552
4552
4552
4552
255
Fan Start/Cooling Setting
0
Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255
60
1
Fan2 Initial Volt
0-255
60
2
Fan3 Initial Volt
Fan Start Voltage (0.1V)
0-255
60
3
Fan4 Initial Volt
0-255
40
4
Fan5 Initial Volt
0-255
40
5
Fan6-8 Initial Volt
0-4095
1845
8
Cooling Time
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
1-15
3
10
Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15
3
11
OnStart Cooling Start Threshold
0-100
60
12
After shutdown cooling
Cooling Operation after Shut Down (0: No, 1: Yes)
0-1
1
256
Fan Lamp Voltage Down Setting
0
Lamp Voltage
Current Lamp Voltage (1V) (Read only)
0-255
---
1
Lamp Vol Threshold
Threshold Voltage (1V)
30-90
30
2
Fan1 Speed Gain
Fan Speed Ad Gain (0.1V)
0-1500
0
257
Fan Setting at Dimmer
0
Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10
1
258
Fan Control Range Setting (for Lamp2)
0
High Fan4 Min (LAMP2)
Fan Spinning (Min/Max) (rpm)
0000 - 9990
5200
3256
5200
5200
1
High Fan4 Max (LAMP2)
0000 - 9990
5200
3256
5600
5600
2
High Fan5 Min (LAMP2)
0000 - 9990
3256
5200
3256
3256
3
High Fan5 Max (LAMP2)
0000 - 9990
3256
5200
3656
3656
4
Normal Fan4 Min (LAMP2)
0000 - 9990
4424
2880
4424
4424
5
Normal Fan4 Max (LAMP2)
0000 - 9990
4424
2880
4824
4824
6
Normal Fan5 Min (LAMP2)
0000 - 9990
2880
4424
2880
2880
7
Normal Fan5 Max (LAMP2)
0000 - 9990
2880
4424
3280
3280
8
Eco Fan4 Min (LAMP2)
0000 - 9990
3640
2504
3640
3640
9
Eco Fan4 Max (LAMP2)
0000 - 9990
3640
2504
4040
4040
10
Eco Fan5 Min (LAMP2)
0000 - 9990
2504
3640
2504
2504
11
Eco Fan5 Max (LAMP2)
0000 - 9990
2504
3640
2904
2904
259
Fan Air Pressure Setting
0
Press Source Range Low
Pressure Sensor Control Range (AD)
0-1024
646
1
Press Source Range High
0-1024
424
2
Press Fan Add Range High(lamp
in)(High)
Add Spinning (Lamp Intake fan)
0 - 5000
160
3
Press Fan Add Range Low(lamp
in)(High)
0 - 5000
640
4
Press Fan Add Range High(no
lamp in)(High)
Add Spinning (without Lamp Intake fan)
0 - 5000
720
5
Press Fan Add Range Low(no
lamp in)(High)
0 - 5000
1432
6
Press Fan Add Range High(lamp
in)(Normal)
Add Spinning (Lamp Intake fan)
0 - 5000
200
7
Press Fan Add Range Low(lamp
in)(Normal)
0 - 5000
1552
8
Press Fan Add Range High(no
lamp in)(Normal)
Add Spinning (without Lamp Intake fan)
0 - 5000
720
9
Press Fan Add Range Low(no
lamp in)(Normal)
0 - 5000
1432
10
Press Fan Add Range High(lamp
in)(Eco)
Add Spinning (Lamp Intake fan)
0 - 5000
96
11
Press Fan Add Range Low(lamp
in)(Eco)
0 - 5000
896
12
Press Fan Add Range High(no
lamp in)(Eco)
Add Spinning (without Lamp Intake fan)
0 - 5000
720
13
Press Fan Add Range Low(no
lamp in)(Eco)
0 - 5000
1432
14
Temp A Warning (High)(Highland) Temp A Error at High
0 - 100
46
15
Temp B Warning (High)(Highland) Temp B Error at High
0 - 100
60
16
Temp C Warning (High)(Highland) Temp C Error at High
0 - 100
55
Summary of Contents for PLC-WTC500AL
Page 102: ... 102 IC Block Diagrams NJW1141 Audio Selector IC5111 L3E07111 LCD DRIVE DIGITAL GAMMA IC401 ...
Page 103: ... 103 IC Block Diagrams M62393 DAC IC7971 NJM2671 Motor Controller IC7601 ...
Page 104: ... 104 IC Block Diagrams LC87F2G08A MCU IC4501 PW392 Scaler IC301 ...
Page 105: ... 105 IC Block Diagrams PW610 Keystone IC2301 TE7783 I O Expander IC4801 ...
Page 106: ... 106 IC Block Diagrams TPA3123 Audio Output IC5051 ...
Page 162: ... KV5AM Dec 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 174: ...A12 SCH_KV5AM NO DATA ...