Appendix
This projector provides a function to control and monitor the projector's operations by using the RS-232C
serial port.
Connect a RS-232C serial cross cable to CONTROL
PORT on the projector and serial port on the PC.
(See p.19)
Launch a communication software provided with PC
and setup the communication condition as follows:
1
2
3
Baud rate : 9600 / 19200 bps
Parity check
: none
Stop bit
: 1
Flow control
: none
Data bit
: 8
Type the command for controlling the projector and
then enter the "Enter" key.
Example
When you want to change the input to INPUT 2,
Type 'C' '0' '6' 'Enter'.
Note:
Enter with ASCII 64-byte capital
characters and one-byte characters.
Note:
The default of the baud rate is set to
19200 bps
. If an error occurs in the
communication, change the serial port
and the communication speed (baud
rate).
Serial Control Interface
Operation
List of Picture in Picture
o : Picture in Picture combinations are enabled.
x : Picture in Picture combinations are disabled.
Note:
• When the input signal(s) is/are incompatible,
X
mark will be displayed on the Main/Sub picture.
• Depending on the frequency or signal type of PC/AV input, the display resolution may be lowered
or images may not be displayed on the Main/Sub picture.
<Display resolution is lowered when;>
• Inputting PC analog signals: Between 100-162 MHz
<Images are not displayed and X mark appears when;>
• Inputting PC analog signals: More than 162 MHz
• Inputting PC digital signals: More than 100 MHz
• Inputting AV digital signals: 1080p
<Picture in Picture is disabled when;>
• Inputting signal formats: WUXGA 1, WXGA+2, UXGA 2, UXGA 3, UXGA4, D-1080p
95
Summary of Contents for PLC-HP7000L