-29-
After replacing the Power Board, readjust the Output
voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D.
2. Adjust the voltage by using VR671 as following.
AC Input
Reading
230V 370V
±2V
120V
320V ±2V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
1. Receive the 16-step gray scale video signal.
2. Set to VIDEO mode.
3. Connect a digital voltmeter to pin 2 (+) of K6E and
chassis ground (-).
4. Adjust voltage to 6.2 ±0.1V by using VR662.
1. Receive the 16-step gray scale video signal.
2. Set to VIDEO mode.
3. Connect a digital voltmeter to pin 5 (+) of K6E and
chassis ground (-).
4. Adjust voltage to 15.6 ±0.1V by using VR661.
1. Receive the 16-step gray scale video signal.
2. Set to VIDEO mode.
3. Connect a digital voltmeter to pin 5 (+) of K6J and
chassis ground (-).
4. Adjust voltage to 12.0 ±0.1V by using VR681.
+12V ADJUSTMENT
+15V ADJUSTMENT
+6V ADJUSTMENT
OUTPUT VOLTAGE ADJUSTMENT
●
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of perfor-
mance and product safety.
[Adjustment Condition]
●
Input signal
Video signal -------------- 1.0Vp-p/75
Ω
terminated, 16 steps gray scale or color bar pattern
Computer signal -------- 0.7Vp-p/75
Ω
terminated, 16 steps gray scale pattern
●
Picture control mode ---------- “NORMAL” mode unless otherwise noted.
Note: Please refer to “Service Adjustment” for entering to the service mode and adjusting the service data.
Electrical Adjustments
1. Receive the NTSC color bar video signal.
2. Set to VIDEO mode.
3. Enter to the service mode, select data no. “030” and
change data value upward or downward. Confirm that
the data value automatically change and stay a cer-
tain value.
DVCO ADJUSTMENT
Presetting
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
[R-DC ADJUSTMENT]
3. Connect a digital voltmeter to test point “TP2511” (+)
and chassis ground (-).
4. Enter to the service mode, select data no. “000” and
change data value to adjust voltage to 7.5 ±0.1V.
[G-DC ADJUSTMENT]
5. Connect a digital voltmeter to test point “TP2512” (+)
and chassis ground (-).
6. Enter to the service mode, select data no. “001” and
change data value to adjust voltage to 7.5 ±0.1V.
[B-DC ADJUSTMENT]
7. Connect a digital voltmeter to test point “TP2513” (+)
and chassis ground (-).
8. Enter to the service mode, select data no. “002” and
change data value to adjust voltage to 7.5 ±0.1V.
DC ADJUSTMENT
Summary of Contents for PLC-EF10BA
Page 55: ... 54 IC Block Diagrams AV9155C OSC IC3301 IC3321 CIP3250A Component Interface Processor IC102 ...
Page 58: ... 57 IC Block Diagrams ML60851ATB USB Controller IC3801 MPC948FA Clock Driver IC3341 ...
Page 59: ... 58 IC Block Diagrams M62358FP DAC IC1401 VPC3215C Digital Video Processor IC101 ...
Page 60: ... 59 IC Block Diagrams MB40988PFQ D A Converter IC1181 MSM54V16258 DRAM IC2301 IC2311 ...
Page 61: ... 60 IC Block Diagrams CXA2016S Sync Separator IC4141 TC4052BF Sync Separator IC4141 ...
Page 66: ... 65 TDA8395T SECAM Decoder IC6103 IC Block Diagrams ...
Page 109: ...Nov 99 1300 SI Printed in Japan SANYO Electric Co Ltd ...