3. Description of adjustment   

3.1 Unit adjustment 

Connect the digital processing board, analog board, power board, power filter board and button 
board according to the wiring diagram. Connect with power and observe the display. 
3.2 Method for using factory menu 
Press ”Source” button, then press”2580” to enter level one factory menu. Press ”

” and “

“ to 

select adjustment page of the level one factory menu, then press “OK” to access. Press “

” and 

“ to move cursor up and down, when the cursor stays on a certain adjustment item, you can 

adjust it according the prompt. Press “MENU” exit to the level one factory menu; press “MENU” 
again to exit from the factory menu. The adjustment item is list as table 1. 

Table 1 adjustment item 

No. 

Item  

Specification  

Factory Preset 

Reset to the default data 

2 Spatial 

NR 

3 Speckel 

NR 

4 Temporal 

NR 

Noise reduce setting, the preset data of each 
channel is different, please don’t change it. 

White Balance 

White balance adjustment 

Auto Color 

A/D correction 

DTV Manual Scan 

If search DTV at manual scan, default= Off 

 
3.3 adjustment of white balance 
3.3.1 input 16 level gray-scale signal from VG849 to HDMI channel (TMIING: select a support 
format of HDMI), enter white balance adjustment page of factory menu, select cool color 
temperature of item, fixed GG to 5000, adjust RG, BG, let the color coordinate of third level on the 
right be (270,283) at 120nits; fixed BO to 5000, adjust RO, GO, let the color coordinate of third level 
on the left be (270,283) at 5nits. The brightness of 120nits and 5nits may obtain by adjusting the 
contrast and brightness of menu. 
3.3.2 input 16 level gray-scale signal from VG849 to AV channel (TMIING:968), enter white balance 
adjustment page of factory menu, select cool color temperature of item, fixed GG to 5000, adjust 
RG, BG, let the color coordinate of third level on the right be (270,283) at 120nits; fixed BO to 5000, 
adjust RO, GO, let the color coordinate of third level on the left be (270,283) at 5nits. The brightness 
of 120nits and 5nits may obtain by adjusting the contrast and brightness of menu. 
3.3.3 input 16 level gray-scale signal from VG849 to VGA channel (TMIING: select a support format 
of VGA), enter white balance adjustment page of factory menu, select cool color temperature of 
item, fixed GG to 5000, adjust RG, BG let the color coordinate of third level on the right be (270,283) 
at 120nits; fixed GO to 5000, adjust RO, BO, let the color coordinate of third level on the left be 
(270,283) at 5nits. The brightness of 120nits and 5nits may obtain by adjusting the contrast and 
brightness of menu. 
3.3.4 input 16 level gray-scale signal of 480P from VG849 to YPbPr channel, enter white balance 
adjustment page of factory menu, select cool color temperature of item, fixed RG, GG, BG to 5000, 
and RO to 5000, adjust RO, BO, let the color coordinate of third level on the left be (270,283) at 
5nits. The brightness of 5nits may obtain by adjusting the contrast and brightness of menu. 
Note: the white balance adjustment of VGA and YPBPR must be done at the situation that the white 
balance adjustment of HDMI is accurate.     

 

Summary of Contents for PDP-42XR7Z

Page 1: ...PRODUCT CODE No 1 682 344 45 PAL SECAM SERVICE MANUAL PDP TV PDP 42XR7Z FILE NO REFERENCE No SM0915018 ...

Page 2: ...instructions Method of software upgrading Working principle analysis of the unit Block diagram IC block diagram Wiring diagram Troubleshooting guide Schematic diagram APPENDIX A Assembly list APPENDIX B Exploded View 1 3 6 13 14 15 22 23 32 ...

Page 3: ...heat radiation parts or direct exposure to sunlight Otherwise there will be kickbacks 1 5 In case foreign substances such as water liquid metal slices or others fall into the module carelessly power must be cut off immediately Keep the module as it is and do not move anything on the module Otherwise it might be possible to contact the high voltage or cause shock short circuit so that it may lead t...

Page 4: ...d for a long time difference in its brightness and color may occur compared with movable pictures But it doesn t show any problem and the reason is that there is reduced density of fluorescent powder in the former On the other hand even if changes take place in the picture it can keep its brightness for a period of time several minutes It s a feature inherent with plasma and it s not abnormal Howe...

Page 5: ...V VGA HDMI signal generator CA100 white balancer 2 The alignment flow chart see below figure Fig 1 adjustment flow chart Check DDC and FLASH To produce digital board and analog board All testing Adjust white balance Connect with central signal source then check each function of TV such as station missing analog control etc check the output of headphone and speaker Input AV SVIDEO signal then check...

Page 6: ... third level on the left be 270 283 at 5nits The brightness of 120nits and 5nits may obtain by adjusting the contrast and brightness of menu 3 3 2 input 16 level gray scale signal from VG849 to AV channel TMIING 968 enter white balance adjustment page of factory menu select cool color temperature of item fixed GG to 5000 adjust RG BG let the color coordinate of third level on the right be 270 283 ...

Reviews: