static electricity. During maintenance operation be sure to cover yourself with anti-static bag and 
before operation make sure to have it sufficiently grounded.       
1.11 There are a big number of connection wires distributed around the screen. Please take care 
not to touch or scuff them during maintenance or removing the screen, because once they are 
damaged the screen will fail to work and it’s not possible to repair it. 
If the connection wires, connectors or components fixed by the thermotropic glue need to disengage 
when service, please soak the thermotropic glue into the alcohol and then pull them out in case of 
damage. 
1.12 Connector for the circuit board of the screen part is relatively fine and delicate. Please take 
care in the replacement operation lest it should get damaged. 
1.13 Special care must be taken during transportation and handling because strenuous vibration 
could lead to screen glass breakage or damage on the driving circuitry. Be sure to use a strong 
outer case to pack it up before transportation or handling.   
1.14 Please put it for storage in an environment in which the conditions are under control so as to 
prevent the temperature and humidity from exceeding the scope stipulated in the specification. For 
prolonged storage please cover it with anti-moisture bag and have them piled and stored in one 
place. The environmental conditions are tabulated as below:       

Temperature 

Scope for operation 

0~50centigrade 

 

Scope for storage 

-15~60centigrade 

Humidity 

Scope for operation 

20%~80% 

 

Scope for storage 

20%~80% 

1.15 If a fixed picture is displayed for a long time, difference in its brightness and color may occur 
compared with movable pictures. But it doesn’t show any problem and the reason is that there is 
reduced density of fluorescent powder in the former. On the other hand, even if changes take place 
in the picture, it can keep its brightness for a period of time (several minutes). It’s a feature inherent 
with plasma and it’s not abnormal. However please try as much as possible to avoid showing a still 
picture of high brightness for a long time during operation.     
1.16 As a digitalized display devise, this module is provided with error diffusion technology and the 
gray scale and false enhancement of contour can be displayed by reusing of sub-field. As compared 
with cathode ray tube, it can be found in the moving picture that at the brim of the face of a person 
there are some wrong colors. 
1.17 During the display of graph (indicating the gradual change in brightness horizontally or 
vertically) resulting from gray scale test it can be found that the brightness for the two adjacent 
levels is uneven. This is caused by the reuse of sub-field, the display of load rectification and the 
electrolysis. 
1.18 The screen front plate is of glass. Please make sure that the screen has been put in place 
during erection. If it is not in place before the erection begins it may lead to screen crack or 
breakage.   
1.19 Make sure the screw used in the mounting of the screen is of the original specs lest it should 
cause damage to the screen due to mismatch. Special care should be taken not to use too long or 
too big screw. 
1.20 Care must be taken to guard against dust during assembling or dismantling, especially to avoid 
dirt from falling in between the screen and the glass lest it should harm the receiving and viewing 

Summary of Contents for PDP-42XR7Z

Page 1: ...PRODUCT CODE No 1 682 344 45 PAL SECAM SERVICE MANUAL PDP TV PDP 42XR7Z FILE NO REFERENCE No SM0915018 ...

Page 2: ...instructions Method of software upgrading Working principle analysis of the unit Block diagram IC block diagram Wiring diagram Troubleshooting guide Schematic diagram APPENDIX A Assembly list APPENDIX B Exploded View 1 3 6 13 14 15 22 23 32 ...

Page 3: ...heat radiation parts or direct exposure to sunlight Otherwise there will be kickbacks 1 5 In case foreign substances such as water liquid metal slices or others fall into the module carelessly power must be cut off immediately Keep the module as it is and do not move anything on the module Otherwise it might be possible to contact the high voltage or cause shock short circuit so that it may lead t...

Page 4: ...d for a long time difference in its brightness and color may occur compared with movable pictures But it doesn t show any problem and the reason is that there is reduced density of fluorescent powder in the former On the other hand even if changes take place in the picture it can keep its brightness for a period of time several minutes It s a feature inherent with plasma and it s not abnormal Howe...

Page 5: ...V VGA HDMI signal generator CA100 white balancer 2 The alignment flow chart see below figure Fig 1 adjustment flow chart Check DDC and FLASH To produce digital board and analog board All testing Adjust white balance Connect with central signal source then check each function of TV such as station missing analog control etc check the output of headphone and speaker Input AV SVIDEO signal then check...

Page 6: ... third level on the left be 270 283 at 5nits The brightness of 120nits and 5nits may obtain by adjusting the contrast and brightness of menu 3 3 2 input 16 level gray scale signal from VG849 to AV channel TMIING 968 enter white balance adjustment page of factory menu select cool color temperature of item fixed GG to 5000 adjust RG BG let the color coordinate of third level on the right be 270 283 ...

Reviews: