26
−
2.
2.
2.
2.
Temperature control and High, Low temperature alarm
<Temperature control>
Setting range
:
-18
℃~
-40
℃
Display range
:
-50
℃~
+50
℃
Setting method
:
Press SET key and set the required value with key and
Key. Press SET key again to memorize the set value,
And then return to PV display.
Out
of setting range : If change to out of setting range value by mistake and press
SET key , buzzer sound continuously for 1 second.
<Alarm>
High temperature alarm
:
When the internal temperature is higher than SV (
+
5
℃~
+15
℃
), alarm lamp and
digital display is blinking. After 15min.later, buzzer will sound and remote alarm
contact
will turn ON. (initial value: +10
℃
)
Low temperature alarm
:
When the internal temperature is lower than SV
(
-5
℃~
-15
℃)
, alarm lamp and digital
display is blinking. After 15min.later, buzzer will sound and remote alarm contact will
turn ON. (initial value: -10
℃
)
Setting method
:
Keep pressing key over 5 seconds to enter function mode (“F00”).
Then press key to count up value. Change “F01” to input high temperature alarm
value, “F02” to input low temperature alarm value.
Set either “F01” or “F02” then press SET key to turn alarm temperature setting mode
to set required value with key and key.
Press SET key again to memorize value.
Out of setting range
:
If
change to out of setting range value
by mistake
and press SET key
,
sound buzzer
continuously for 1second and
remain in setting mode to maintain the setting value.
3.
3.
3.
3.
Defrosting
This function is different by each model code (products) .
a. In PV display keep pressing DEF key over 5 seconds, defrosting will be started.
Model code 001 (MDF-U333) --- Force to turn compressor OFF.
Model code 002 (MDF-U537) --- Force to turn compressor & solenoid valve OFF. (Use 1 solenoid valve)
Model code 003 (MDF-U537D)
--- Single compartment
→
Force to turn OFF solenoid valve at the ROOM lamp illuminated.
--- Both compartments
→
Force to turn OFF 2 solenoid valves & compressor.
b. Press again DEF key to quit defrosting.
(
Manual start and
finish
)
Summary of Contents for MDF-U333
Page 12: ... 9 Dimensions MDF U333 ...
Page 13: ... 10 Dimensions MDF U537 ...
Page 14: ... 11 Dimensions MDF U537D ...
Page 18: ... 15 Refrigeration circuit principle diagram MDF U333 ...
Page 19: ... 16 Refrigeration circuit welding points MDF U333 ...
Page 20: ... 17 Refrigeration circuit principle diagram MDF U537 ...
Page 21: ... 18 Refrigeration circuit welding points MDF U537 ...
Page 22: ... 19 Refrigeration circuit principle diagram MDF U537D ...
Page 23: ... 20 Refrigeration circuit welding points MDF U537D ...
Page 37: ... 34 Wiring diagram ...
Page 38: ... 35 ...
Page 39: ... 36 ...
Page 40: ... 37 Circuit diagram Main PCB ...
Page 41: ... 38 Components on PCB Main PCB ...
Page 52: ... Memorandum ...