General Installation Manual 
 

SPECIFICATIONS  
 

 
 

 

Electrical Specifications 

Model 

HIP-225HDE1 

HIP-225HDE1-2 

HIP-220HDE1 

HIP-220HDE1-2 

HIP-215HDE1 

HIP-215HDE1-2 

Cell Number in Series 

60 

60 

60 

Total cell number 

240 

240 

240 

Rated Power, Watts (Pmax) 

225 

220 

215 

Maximum Power Voltage (Vpm) 

33.9 

33.5 

33.1 

Maximum Power Current (Ipm) 

6.64 

6.57 

6.50 

Open Circuit Voltage (Voc) 

41.8 

41.4 

40.9 

Short Circuit Current (Isc) 

7.14 

7.07 

6.99 

Cell Type 

HIT* 

HIT* 

HIT* 

Maximum System Voltage  

1000 

1000 

1000 

Maximum Over-current protection rating (A) 

15 

15 

15 

Factory Installed Bypass Diodes 

Mechanical Specifications 
Length, mm 

1610 

Width, mm 

861 

Thickness, mm 

35 

Weight, kg 

16.5 

 

 
 
 
 

                                                                       

 

 
 
 
 

 

 

               

1 0 0 0 V

P V U - B 5 0 . 2

I P 6 5

            

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure2: Configuration of 

junction box 

negative(-) 

po) 

Cable 

Connector 
(MC Plug) 

Figure3-1 : Dimensions 

Dimension in mm 

Dimensions 

Note : In case of installation on a rail structure, 
           modules must be attached within the depicted shaded range. 

Section A-A’ 

Section B-B’ 

Junction box 

2-

Φ

Mounting Places 
(4 places) 

 

Summary of Contents for HIP-225HDE1

Page 1: ...odule Do not puncture or damage the back sheet of a module to avoid the hazard of electric shock and fire To avoid the hazard of electric shock and injury children and unauthorized persons should not be allowed near the installation of PV modules To avoid the hazard of electric shock and injury be sure to completely ground all modules To avoid the hazard of electric shock fire and injury do not di...

Page 2: ...modules are as follows 1 The modules should be operated only in terrestrial applications No space or other Special Conditions see below 2 The ambient temperature should be within 20 C 4 F to 40 C 104 F 3 The relative humidity should be within 45 to 95 4 The installation place should be less than 1 000m 3 280ft above sea level Installations more than 1 000m 3 280ft are allowed only if the wind pres...

Page 3: ... all non conductive coatings such as paint anodized coatings or vitreous enamel A wiring terminal or bonding location of module intended to accommodate a field installed equipment grounding conductor shall be identified with the appropriate symbol IEC 60417 5019 DB 2002 10 or shall have a green colored part Grounding should be carried out by the attachment to the module or array frame to avoid the...

Page 4: ...uous improvement SANYO reserves the right to change product specifications at any time without prior notice For further information please visit www sanyo com or contact a SANYO Authorized Representative 2007 Dec SANYO Electric Co Ltd All Rights Reserved 12 28 07 ...

Page 5: ...rrent Isc 7 14 7 07 6 99 Cell Type HIT HIT HIT Maximum System Voltage 1000 1000 1000 Maximum Over current protection rating A 15 15 15 Factory Installed Bypass Diodes 3 3 3 Mechanical Specifications Length mm 1610 Width mm 861 Thickness mm 35 Weight kg 16 5 1 0 0 0 V P V U B 5 0 2 I P 6 5 Figure2 Configuration of junction box negative positive Cable Connector MC Plug Figure3 1 Dimensions Dimension...

Page 6: ...nual 6 Dimension in mm Optional Mounting Range Dimension in mm Optional Mounting Range Note Fixing span is 1050mm or less Note Fixing span is 1050mm or less Figure3 2 Optional Mounting Range Figure3 3 Optional Mounting Range ...