MONITOR (MIDDLE) INTERLOCK
SWITCH

This interlock switch disables the control panel
if the door is open or the catch is out of adjust-
ment or the primary interlock switch fails.
If for some reason the primary switch and sec-
ondary switch stick in the closed position and
the door were to be opened, the circuit would
be shorted through the normally closed safety
switch. This would blow the fuse.

If there appears to be an interlock switch prob-
lem, but the fuse is not blowing, refer to the
Component Test Procedure Section in this
service manual.

NOTE:

IF THE INTERLOCK SWITCHES ARE

REPLACED, THE CATCH MUST BE ADJUST-
ED. SEE DOOR AND INTERLOCK ADJUST-
MENTS SECTION FOR PROPER ADJUST-
MENT PROCEDURE. DEFECTIVE SWITCHES
SHOULD BE DESTROYED TO PREVENT
POSSIBLE FUTURE USE.

IMPORTANT: 

IF AT ANY TIME THE OVEN

FUSE BLOWS  DUE TO AN OVEN FAULT, OR
THE CIRCUIT BREAKER TRIPS AFTER BEING
RESET ONE           TIME WITH THE HOUSE
CIRCUIT UNLOADED EXCEPT FOR THE
OVEN, THE INTERLOCK SWITCHES MUST
BE REPLACED AS A GROUP. THIS IS
BECAUSE THE SHORT CIRCUIT CURRENTS
WILL HAVE DAMAGED THESE IMPORTANT
SWITCHES.

MAGNETRON THERMAL PROTECTOR

The magnetron thermal protector located on
the magnetron is designed to prevent an over-
heated condition in the tube due to fan failure,
obstructed air ducts, etc.
Under normal operating conditions, the thermal
protector remains closed. However, If abnor-
mally high temperatures within the magnetron
approach a critical level, the thermal protector
will  interrupt the circuit to the magnetron. When
the magnetron has cooled to a safe operating
temperature, the thermal protector closes and a
cook (or defrost) cycle can be resumed. 

HALF-WAVE VOLTAGE DOUBLER CIRCUIT

The half-wave rectification circuit consists of a
diode package and a single capacitor. The 

2070

Volts AC from the high voltage secondary wind-
ing is rectified to approximately 

4140

 Volts DC

(peak voltage) needed for magnetron operation.
1. Diode - a diode is a solid state device that

allows current flow in one direction, but pre-
vents current flow in the opposite direction. 

2.  Capacitor - a capacitor is able to store elec-

tric energy, as well as pass AC and block DC
current. 

WATER TEMPERATURE RISE CHECK 

The following procedure should be followed
when low power is suspected in the oven but all
other operations, including cooking light opera-
tion, appear normal. 
Power output of the magnetron can be meas-
ured by performing a water temperature rise
check. This test will require a quart glass cup
and an accurate mercury thermometer or ther-
mocouple-type temperature tester. For accu-
rate results the following procedure must be fol-
lowed carefully. 

1. Fill a measuring cup with one quart of tap

water and measure temperature of the
water with a thermometer or thermocouple
tester. Stir the temperature probe through
the water until the temperature stabilizes.
Record the temperature of the water and
remove the temperature probe. 

2.  Place the measuring cup in the oven and put

the oven into the cook (high) cycle for exactly
two (2) minutes. Allow the water to heat. 

3.  Remove cup from the oven and again meas-

ure temperature making sure to stir the tem-
perature probe through the water until max-
imum temperature is recorded. 

4. Subtract the cold water temperature from

the hot water temperature. The result should
be 

10

°

C

±

2

°

C

, or between 

8

°

C

 to 

12

°

C

 rise

in temperature. If the water temperature is
accurately measured and tested for the
required time period, the test result will indi-
cate if the magnetron tube has low power
output (low rise in water temperature) which
would extend cooking time, or high power
output (high rise in water temperature)
which would reduce cooking time. 

Because cooking times can be adjusted to
compensate for power output, the magnetron
tube assembly should be replaced only if the
water temperature rise test indicates a power
output well beyond the normal limits. This test
is only accurate if the power supply line voltage
is 

230

 Volts while the oven is operating.

ALTERNATE TEST-METRIC

Use same procedure as in preceding para-
graphs except as noted.
1.  Use 1000 ML water.
2. Timer for two minutes.
3. Same
4. Water temperature will be between 

8

°

C

 to

1

2

°

C

 higher.

ELECTRICAL OPERATION

By closing the door, the primary and secondary
interlock switches close and monitor switch
opens. The closed switches allow line voltage to
flow through the 

10

 amp fuse to interlock to

magnetron thermal switch. At this point, line
voltage splits and power is applied to primary
side of high voltage transformer, oven cavity
light, fan motor, and timer.
To complete the circuit, two things must happen
to energize the above Components. The timer
must be set, which will close timer contacts,
and the door must be closed, which activates
the interlock switches. At this time, line voltage
to neutral is applied across high voltage pri-
mary, timer, oven light, and fan.
The 

2

3

0 Volt AC input to the primary winding of

the power transformer is converted to approxi-
mately 

2070

 Volts AC output from the high volt-

age secondary winding. At the same time, the
filament secondary winding of the power trans-
former provides 3.

22

 Volts AC to heat the mag-

netron filaments.
The 

2070

 Volts AC output from the power trans-

former high voltage secondary winding is sent
to a half-wave doubling circuit comprised of a
single diode and capacitor where approximate-
ly 

4140

 Volts DC (peak voltage) is provided to

the magnetron tube.
The negative 

4140

 Volts DC applied to the

cathode of the magnetron tube causes the

magnetron to oscillate and produce the 2450
MHz cooking frequency.
The microwave energy produced by the mag-
netron tube is channeled through a waveguide
into the cavity past the diffuser and finally into a
cavity where the load is placed to be heated.
When the timer has completed the selected
cooking time, the timer  switch opens. The cir-
cuits are open to the light, timer, fan motor, and
power transformer, and the microwave energy
is no longer produced. Five beeps signal the
end of the cook cycle.

DOOR & INTERLOCK ADJUSTMENTS

DOOR ADJUSTMENTS

The door adjustment on all microwave ovens is
very important to prevent any excessive leak-
age. The microwave leakage levels should be
checked after all door, interlock switches and
associated repairs are made. See the
Microwave Radiation Test Section in this man-
ual for proper testing procedures.

The following door adjustments must be fol-
lowed.

LATCH & CATCH ASSEMBLY ADJUST-
MENTS

CAUTION: 

AFTER REMOVING THE CABI-

NET, DISCHARGE       THE CAPACITOR BY
PLACING AN INSULATED SCREWDRIVER
ACROSS THE TERMINALS.
To make proper latch and catch assembly
adjustment:
1.  Disconnect the power to the unit, remove

the cabinet and   discharge the capacitor by
placing an insulated screwdriver across the
terminals.

2.  Open the door.
3.  Loosen the screws that secure the plastic

interlock bracket   until the assembly can
be moved freely back and forth.

4.  Hold the door closed securely.
5.  Move the plastic catch toward the door until

it stops and door is latched. Next, move the
catch toward the back panel making sure it
is snug against door latch. Check by open-
ing and closing the door. Using an ohmme-
ter, place the leads of the meter across the
terminals of the monitor switch. As the door
is opened, your meter should show a short,
as the door is closed it should show an
open circuit.

4

Summary of Contents for EM-FL50N

Page 1: ...hazards developing due to improper assembly or adjustment While mak ing such repairs persons not having the proper background may subject themselves to the risk of injury or electrical shock which can be serious or even fatal A If the oven is operative prior to servicing a microwave emission check should be performed prior to servicing the oven B Inform the manufacturer importer or assembler of an...

Page 2: ...dance with the National Electrical Codes DO NOT use a two prong adapter since proper grounding is not assured even if the ground wire or metal tab is connected to the outlet box The use of an extension cord is not recom mended However if it is necessary to use an extension cord it must be a type s with 3 num ber 16 wires and have a 3 prong grounded plug The extension cord should not drape over a c...

Page 3: ... completely safe during normal operation However carelessness in servicing the oven can result in an electric shock or pos sible danger from a short circuit You are asked to observe the following precau tions carefully 1 Always remove the power plug from the out let before servicing 2 Use an insulated screwdriver and wear rub ber gloves when servicing the high voltage side 3 Discharge the high vol...

Page 4: ... would extend cooking time or high power output high rise in water temperature which would reduce cooking time Because cooking times can be adjusted to compensate for power output the magnetron tube assembly should be replaced only if the water temperature rise test indicates a power output well beyond the normal limits This test is only accurate if the power supply line voltage is 230 Volts while...

Page 5: ...any suspected high voltage problem 1 Unplug oven from its power source 2 After removing the cabinet discharge the capacitor by shorting the two capacitor ter minals together with an insulated screw driver 3 Visually check the high voltage wiring for proper connections Refer to wiring dia gram for proper wiring sequence CAUTIONS HIGH VOLTAGES ARE PRE SENT DURING THE COOK HIGH CYCLE SO EXTREME CAUTI...

Page 6: ...n both directions or if an infinite resistance is read in both directions the diode is probably defective and should be replaced If the diode check is normal go to Magnetron Check CHECKING H V DIODES ALTERNA TIVE METHOD Many times the diode you check as open is probably good We have found that many of you are checking them out on the wrong scale of your meter or that your meter is physically not a...

Page 7: ...REPLACING THE FUSE IMPORTANT IF THE 10 AMP FUSE BLOWS REFER TO THE TESTING PROCE DURE DO NOT REPLACE IT UNTIL THE PROBLEM IS CORRECTED ALSO IF AT ANY TIME THE OVEN FUSE BLOWS DUE TO AN OVEN FAULT OR THE CIRCUIT BREAKER TRIPS AFTER BEING RESET ONCE WITH THE HOUSE CIRCUIT UNLOADED EXCEPT FOR THE OVEN THE INTERLOCK SWITCHES MUST BE REPLACED AS A GROUP THIS IS BECAUSE THE SHORT CIRCUIT WILL HAVE DAMAG...

Page 8: ... the green ground wire under the screw ELECTRONIC CONTROLLER ASSEM BLY REMOVAL 1 Disconnect power from the unit Remove the cabinet and discharge the capacitor 2 Remove screw at top that holds the control panel to the oven chassis 3 Controller can be replaced by removing screws through rear of control panel and replacing with new control wire for wire Reverse above steps to reinstall 4 NOTE The onl...

Page 9: ...UNIT FAN CL CONTROL BOARD TURN TABLE MOTOR MG MONITOR SWITCH TRANSFORMER CN1 KEY BOARD 1 2 3 4 5 6 7 8 9 10 CAPACITOR DIODE MAGNETRON CONDITIONS DOOR CLOSED TIMER ON POWER SELECTOR SWITCH MICROWAVE CAVITY LIGHT TP3 TP1 TP2 TP4 TP6 TT BM MAGNETRON THERMAL SWITCH HV FUSE 0 65A TP7 0 5 ohms 10W CIRCUIT DIAGRAM FOR 1 0 cf Touch 230V NC NO 9 ...

Page 10: ...1 2 3 18 19 31 24 21 27 28 34 44 30 39 17 32 29 38 9 15 35 7 16 Exploded View Model EM FL50N 8 10 11 12 12 13 33 36 37 14 23 22 26 20 25 43 4 41 42 6 40 ...

Page 11: ...ISE FILTER UNIT 1 MO S 0688 20 PCB ASSEMBLY PCB N G 1 2 1 MO A 0796 21 SWITCH LEVER 1 1 MO R 0002 22 SWITCH LEVER 2 1 MO R 0740 23 HV FUSE 0 75A 1 432 0 8335 02100 24 SWITCH BRACKET 1 MO R 0440S 25 OPEN LEVER 1 MO R 0739 26 FOOT FRONT 2 MO D 2341 27 FAN 1 MO R 0235N 28 FAN CASING 1 MO R 0439S 29 AIR GUIDE 1 MO R 0471S 30 CAPACITOR HOLDER 1 MO M 0703 31 AC POWER RELAY 1 MO S 0576 32 GLASS TRAY 1 MO...

Reviews: