Room Control Systems Overview

Centralised Control Systems Overview

A wide variety of control options to meet the requirements of different customers.

Operation system

Individual control systems

Timer operation

Requirements

Normal  

operation

Operation from  

each seat

Simple operation

Daily and  

weekly programme

External appearance

Type, model name

Timer wired  

remote controller

RCS-TM80BG

Wireless remote  

controller

RCS-SH80BG.WLB

RCS-TH80BG.WLB

RCS-BH80AG.WLB

RCS-TRP80BG.WLB

RCS-SH1BGB

Simplified remote 

controller

RCS-KR1EG

Schedule timer

SHA-TM64AGB

Number of indoor units which 

can be controlled

1 group, 8 units

1 group, 8 units

1 group, 8 units

64 groups,  

max. 64 units

Use limitations

Up to 2 units can be  

connected per group.

Up to 2 units can be  

connected per group.

Up to 2 units can be  

connected per group.

Power supply from the system 

controller.

When there is no system 

controller, connection is 

possible to the T10 terminal 

of an  

indoor unit.

Connectable 

indoor unit

4 series indoor unit

4 series indoor unit

4 series indoor unit

4 series indoor unit

Function

ON/OFF

-

Mode setting

-

Fan speed setting

-

Temperature setting

-

Air flow direction

-

Permit/Prohibit switching

-

-

-

-

Weekly programme

-

-

*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)

Centralised control systems

Operation with various 

function from central 

station

Only ON/OFF operation from 

central station

Simplified charge ratio for each tenant

Touch screen panel

Personal computer  

(field supply)

External appearance

Type, model name

System controller

SHA-KC64AGB

ON/OFF controller

SHA-KC16KAGB

Intelligent controller

SHA-KT256EG

Communication adaptor

SHA-KA128AGB

Number of indoor units which can be 

controlled

64 groups,  

max. 64 units

16 groups,  

max. 64 units

64 units x 4 systems,  

max. 256 units

2 systems,  

max. 128 units

Use limitations

Up to 10 units can be 

connected to one system.

Main unit/sub unit (1 main 

unit + 1 sub unit) connection 

is possible.

Use without remote controller 

is possible.

Up to 8 units (4 main units + 4 

sub units) can be connected 

to one system.

Use without remote controller 

is impossible.

A communication adaptor 

(SHA-KA128AGB) must be 

installed for three or more 

systems.

Maximum 500 indoor units 

(128 per communication 

adaptor)

Connectable 

indoor unit

4 series indoor unit

4 series indoor unit

4 series indoor unit

4 series indoor unit

Function

ON/OFF

Mode setting

-

Fan speed setting

-

Temperature setting

-

Air flow direction

-

Permit/Prohibit switching

Weekly programme

-

*1

*1

*1

*1

*1

*1

Web 

application

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

Summary of Contents for ECOi C0705DXHN8

Page 1: ...ly general particulars and shall not form any part of the contract For full installation details please contact your SANYO distributor Rating Conditions The cooling and heating capacities are based on the following conditions Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB Outdoor Temperature 7 C DB 6 C WB Printed using paper produc...

Page 2: ... maintenance calls and unit down time Lower running and life cycle costs SANYO ECOi VRF systems are amongst the most efficient VRF systems on the market offering COPs in excess of 4 0 at full load conditions The system is also designed to make sure that we reduce the running cost of each system by using our unique road map control routine to ensure that the most efficient combination of compressor...

Page 3: ...d out with quotations through to installation guidance drawings The new PAC2 system software can be used for all SANYO ECOi GHP and PACi systems The new PAC2 system software can be used for all SANYO ECOi GHP and PACi systems Features include AC Calc Lite included in the package Easy to use system wizards Auto piping and wiring features Converted duties for conditions and pipework Auto CAD DXF exp...

Page 4: ...s designed for creating a comfortable environment when either heating or cooling is required Heat pump systems offer heating or cooling Single footprint size for all unit capacities DC inverter technology combined with R410A for excellent efficiency System configuration from 8HP to 48HP Diversity ratio 50 130 Industry low outdoor unit sound levels from 54 5dB A Quiet mode offers a further 3dB A re...

Page 5: ...HN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 Power supply 380 400 415V 3 phase 50 60Hz Cooling capacity kW 22 40 28 00 33 50 40 00 45 00 50 40 56 00 61 50 68 00 73 00 78 50 85 00 90 00 96 00 101 00 107 00 113 00 118 00 124 00 130 00 135 00 Heating capacity kW 25 00 31 50 37 50 45 00 50 00 56 50 63 00 69 00 76 50 81 50 87 50 95 00 100 00 108 ...

Page 6: ...mperature setting for heating operation has also been extended from 16 C to 30 C 8HP 48HP Cooling 10 C DB 43 C DB Heating 20 C WB 15 C WB Higher COPs lower running costs HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 EER Cooling 3 78 3 45 3 41 3 45 3 38 3 57 3 46 3 44 3 45 3 41 3 4 3 41 3 38 3 45 3 41 3 42 3 42 3 4 3 41 3 40 3 38 COP Heating 4 09 3 95 3 81 3 91 3 79 4 01 3 96 3 8...

Page 7: ... 85 3 79 3 93 3 88 3 84 3 88 3 84 3 81 3 83 3 79 Electric ratings Cooling Running amperes A 10 0 9 5 9 2 13 7 13 0 12 6 16 6 15 7 15 2 20 0 19 0 18 3 23 0 21 8 21 0 23 8 22 6 21 8 27 3 26 0 25 0 30 2 28 7 27 7 33 6 31 9 30 8 36 5 34 7 33 5 39 4 37 5 36 1 43 0 40 8 39 4 45 9 43 6 42 1 47 5 45 1 43 5 50 5 48 0 46 3 53 0 51 0 49 0 57 0 54 0 52 0 60 0 57 0 55 0 63 0 60 0 58 0 66 0 63 0 60 0 69 0 65 0 ...

Page 8: ...75XH SPW UR74GXH56B SPW U095XH SPW UR94GXH56B SPW U125XH SPW UR124GXH56B SPW U165XH SPW UR164GXH56B SPW U185XH SPW UR184GXH56B SPW U255XH SPW UR254GXH56B SPW U365XH SPW UR364GXH56B SPW U485XH SPW UR484GXH56B SPW U605XH SPW UR604GXH56B DR Type Concealed Duct SPW DR254GXH56B SPW DR364GX H56B SPW DR484GX H56B SPW DR764GXH56B SPW DR964GXH56B K Type Wall Mounted Unit SPW K075XH SPW K095XH SPW K125XH KR...

Page 9: ...trol for setting Centralised control systems Operation with various function from central station Only ON OFF operation from central station Simplified charge ratio for each tenant Touch screen panel Personal computer field supply External appearance Type model name System controller SHA KC64AGB ON OFF controller SHA KC16KAGB Intelligent controller SHA KT256EG Communication adaptor SHA KA128AGB Nu...

Page 10: ...a subject to change without notice Fresh air Exhaust air Return air Supply air Humidification optional DX coil Heat exchanger Installation example Timer remote controller RCS TM80BG Simplified remote controller RCS KR1EG Wireless remote controller Controller Options RCS BH80BG WL Rating Conditions Cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB 24 C WB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB C...

Reviews: