– 34 –
SM830078
8. INSTALLATION INSTRUCTIONS
2)
Selecting the Installation Site
AVOID:
ã
areas where leakage of flammable gas may
be expected.
ã
places where large amounts of oil mist exist.
ã
direct sunlight.
ã
locations near heat sources which may
affect performance of the unit.
ã
locations where external air may enter the
room directly. This may cause “sweating”
on the air discharge ports, causing them to
spray or drip.
ã
locations where the remote control unit will
be splashed with water or affected by
dampness or humidity.
ã
installing the remote control unit behind
curtains or furniture.
ã
locations where the receiver in the indoor
unit is exposed to the inverter lamp light.
Faulty operation of the unit occurs.
DO:
ã
select an appropriate position from which
every corner of the room can be uniformly
cooled.
ã
select a location where the ceiling is strong
enough to support the weight of the unit.
ã
select a location where tubing and drain pipe
have the shortest run to the outdoor unit.
ã
allow room for operation and maintenance as
well as unrestricted air flow around the unit.
ã
install the unit within the maximum elevation
difference above or below the outdoor unit
and within a total tubing length from the
outdoor unit as detailed in Table 1.
ã
allow room for mounting the remote control
unit about 3 ft. off the floor, in an area that
is not in direct sunlight nor in the flow of
cool air from the indoor unit.
Air delivery will be degraded if the distance from
the floor to the ceiling is greater than 10 ft..
Indoor Unit
Ceiling-Mounted Type
Recessed Type
3 ft.
3 ft.
3 ft.
3 ft.
3 ft.
1330_X_S
1379_T_I
Front view
The rear of the indoor unit can be installed flush
against the wall.
Min.2ft.
Air intake
Air
discharge
Side view
NOTE
Min.10 inch
Ceiling
Ceiling
Wall
Min.10 inch
NOTE