OUTPUT TERMINALS
WARNING OUT Terminal
œ
The WARNING OUT terminal output becomes 0 V
(Low) in accordance with the (WARNING OUT/EJECT
SET) menu.
WARNING OUT Terminal Output Setting
1
Press the MENU button to display the MAIN MENU.
2
Press the
l
(or
j
) button to select the “5.WARNING
OUT/EJECT SET” line, then press the ENTER
button.
ø
The (WARNING OUT/EJECT SET) menu
appears.
<WARNING@OUT@SET>SET@UP
ALARM@@@@@@@@@@@@Y
NON@REC@@@@@@@@@@N
MECHA.PROBLEM@@@@Y
VIDEO@LOSS@@@@@@@Y
<EJECT@SET>
EJECT@MODE@@@@@@@EJECT1
OPERATION@@@@@@@@SLAVE
3
Press the ENTER button.
4
Press the
l
(or
j
) button to select the desired
mode, then press the ENTER button.
SET UP . . . . Set each item
ALL Y . . . . . . To set all items to “Y”
ALL N . . . . . . To set all items to “N”
œ
If using the “SET UP” setting, continue with steps
5
to
7
.
5
Press the
l
(or
j
) button until the item for warning
output is highlighted, then press the ENTER button.
6
Press the
l
(or
j
) button to set “Y” (warning is
given) or “N” (warning is not given), then press the
ENTER button.
ALARM. . . . . . . . . . . The output becomes 0 V
and “A” appears on the
digital display during alarm
recording
NON REC . . . . . . . . The output becomes 0 V
and “N” appears on the
digital display if the VCR
enters a mode other than
recording (i.e. recording
pause, stop mode, etc.)
during recording
MECHA. PROBLEM
. . . The output becomes 0 V
and “M” appears on the
digital display when the
tape stops or other problem
with the internal mechanism
VIDEO LOSS . . . . . The output becomes 0 V
and “V” appears on the
digital display when there is
no video signal
7
Repeat steps
5
and
6
when setting other items.
8
When finished, press the MENU EXIT button.
NOTES:
œ
The “VIDEO LOSS” line does not appear if “VIDEO
LOSS” is set to “N” in the (GENERAL SET) menu.
œ
Displays on the digital display take precedence over
other displays.
œ
Canceling warning displays and output.
Press the STOP button once.
The warning display disappears from the digital
display.
Press the STOP button once more.
œ
The buzzer will stop when a “VIDEO LOSS” or
“NON REC” warning is output. The buzzer and
these warning outputs will both stop when a
“MECHA. PROBLEM” warning is output.
œ
The “ALARM” warning buzzer and output cannot
be cancelled.
œ
The “VIDEO LOSS” and “NON REC” warning
output cannot be cancelled. Output will stop when
the status returns to the condition before the output
started.
œ
If the system has shut down because of a
“MECHA. PROBLEM” warning, the output is
canceled when the ALL RESET button is pressed.
NF4Q/NA (SRC-850A GB) Tue. Sept., 10/2002