Dimensions

Features

Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver

Power Failure Automatic Restart
Self-Diagnosis
Air Filter
Air Clean Apatite Filter
Quiet Operation
Ion Generator

Options

Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Condensate Drain Pump
Hard Wired Remote Controller
Non-Removeable Locking Remo-con Bracket

Operating Range

 

 

 

    Indoor Air Intake Temp.     Outdoor Air Intake Temp.

Cooling

Maximum

                   95F DB/71F WB                     115F DB

Minimum 

                   67F DB/57F WB                       0F DB

Built-In

Washable, Anti-Mold

Built-In

Available

Knock-out

N/A

Standard

Available

Microprocessor

LCD Wireless Type, Temp. Sensor Built In

             (Horizontal)                                             Manual

24 Hr Program; 1HR ON/OFF

IC Thermostat

Built-In

             (Vertical)                                           Automatic

Sanyo Commercial Solutions

A Division of SANYO North America

1300 Michael Drive 

Wood Dale, IL 60191 USA

www.sanyohvac.com

Available

Standard

Built-In

Built-In

3.  DIMENSIONAL

 D

AT

A

Indoor Unit 

XHS1271 & PNR-XS1872

XHS1872 & PNR-XS1872

6-5/16 6-11/16

1-3/16 (30)

4-19/32

1-25/32

1-25/32

2-3/32

8-15/32

22-5/8 (575)

11-5/32 (283)

3

6

5

Less than 31/32  

Less than 31/32 

3-5/8

22-5/8 (575)

12-7/8

 Suspension bolt pitch

 Suspension bolt pitch

21-1/32 (534)

21-1/32

 (534)

12-7/16

23-5/8 (600)

Ceiling opening dimensions

23-5/8 (600)

Ceiling opening dimensions

7

Center of

panel

24-19/32 (625)

24-19/32 (625)

13-5/32 (334)

14-3/32 (358)

1

2

2

2

2

7-11/16

4-29/32

A View

8

1-3/16

21/32

3-1/8

The length of the suspension

bolts should be selected so that

there is a gap of 1-3/16" or 

the ceiling (21/32" or more

below the lower surface of the 

main unit), as shown in the

figure at right. If the suspension

bolts is too long, it will contact 

the ceiling panel and the unit 

cannot be installed.

AA

Air intake
Discharge outlet
Refrigerant tubing (liquid tube) dia. 1/4" (flared)
Refrigerant tubing (gas tube) dia. 1/2" (flared)
Drain tube connection port VP20 (outer dia. 1")
Power supply port
Suspension bolt hole (4 -  1/2" x 1-1/8" hole)
Fresh air intake duct connection port (dia. 3-7/8")

1
2

3

4
5

6

7
8

7-23/32

1-27/32

1-3/32

2-3/32

2-3/4

1-9/32

5-9/16

25/32

Unit : inch (mm)

17

10-13/16

3-19/32

ID:23/32

4-ID:15/16

21-3/16

6-3/32

4-9/32

2-5/32

Narrow tube service valve

dia.1/4" (6.35)

Wide tube service valve

dia.3/8" (9.52)

3-19/32

15/32

10-7/16 (265)

11-13/32

12-7/16

 

Outdoor Unit

CH1271

Unit : inch (mm)

(852-0-0010-12700-0)

28-11/32 (720)

2-1/8

21-9/16 (548)

5/8

18