1-888-726-8869 www.sanuvox.com
Sanuvox Technologies INC. All rights reserved. 2019-v.1
INSTALLATION MANUAL
You will need a drill and a 1/4 HEX socket to install this kit.
STEP 1
Air Inlet
STEP 2
Air Outlet
1. Remove the two (2) thumb screws.
2. Remove the black frame.
3.
Remove the filter cover.
4. Install the duct adapter plate.
5. Replace the two (2) thumb screws and tighten.
1. Remove the louver.
2. Align the duct adapter plate as per "After" picture.
3. Use a drill with the 1/4 HEX socket and the self taping screws in the kit.
4. Install the duct adapter plate.
| DUCT KIT (OPTIONAL)
Before
Before
After
After
Replacement Parts for VP900 Interceptor
BST120/240GL
120/230 V ballast
MSCFTR7
Metal inlet filter
MSCFTR8
Inlet Grill
MSCMTR8
Motor assembly
MSCCON1
WHITE Gaynor plug for UV lamp
LMPRGJ65
T6 Germicidal 6.5" UV ‘J’ Lamp