GENERAL INSTALLATION
Unit could be
•
Suspended from ceiling with
angles and suspension rods (not
included).
•
Hung on wall with supplied angle
iron (included).
Using 8
’’
collars, attach rigid or flex duct to the return side of
the unit above the area where smoke accumulates in order to
remove as much smoke as possible. Attach duct (metal or flex)
to the supply side of the unit to discharge clean air over door
or entryway. This is done to prevent odors from escaping the
room. It is through recirculation that the odors will be
removed. If the room is longer , you may use multiple inlets
to pull the smoke to the unit.
The VOC controller should be installed on the ceiling or wall -where the smoke will accumulate. The
S300 VOC unit comes with 20ft of wire to link the controller box to the unit. If 20 ft is not long
enough, you can replace it with BX cable with 3 wires.
WORKING INSTRUCTION
The VOC controller analyzes the air every 90 seconds. A 20-foot wire set connects it via a relay to
activate the second oxidizing lamp on demand.
The S300 unit runs continuously, so its regular lamp purifies the air constantly. This dual zone lamp
(UVC / UVV) is enough when there are only one or two smokers.
However, when the cigarette smoke increases in the room, the VOC controller that samples the air
at regular intervals, then triggers the 2nd UVV lamp for periods of 90 seconds. This cycle is repeated
if the controller detects smoke in the room: when there is no more, it then turns off the 2nd lamp,
leaving the 1st lamp to continue the cleaning cycle.
SIMPLIFIED PROCESS
:
•
Ashes in the “white” smoke will be trapped onto the filter
•
Nicotine molecules will be dried by the UVC rays than trapped in the filters without the tar like
material that coats everything.
•
VOC will be oxidised by the UVV, reducing substantially their olfactory perception.
Suggested installation