background image

Page 

5

 of 

5

 

 

 

S300 VOC FOR SMOKING ROOM 

 

USER INSTRUCTIONS 

MAINTENANCE 

 

MONTLY

:   

o

 

Check filter: if filters are dirty, change them (part # 

MSCFTR10

). This will help lower air 

restrictions so to keep up the performance of the unit.  

o

 

Check if the lamps are covered with dust; in that case, clean them with denatured 
alcohol and a clean cloth.

 

 

ANNUALLY: 

o

 

Change lamps (parts -see below) to maintain performance: make sure to put the same 
lamp in the same clamp. Do not interchange lamps as the blue end cap lamp works only 
with the VOC controller. 

 

LMPHGXJ105-1

  

lamp UVC/UVV 

2’’ exposed

 (yellow end cap) 

 

LMPHXJ105

 

 

lamp all UVV (blue end cap)  

 

3-5 years

:  Change VOC controller (

MSC1A)

 

 

WORKING INSTRUCTIONS 

 

The VOC controller analyzes the air every 90 seconds. A 20-foot power cord connects it via a 
relay to the device to activate the second oxidizing lamp on demand. 

 

The S300 VOC unit runs continuously, so its regular lamp purifies the air constantly. This 
dual zone lamp (UVC / UVV) is enough when there are only one or two smokers. 

 

However, if there is much smoke in the room, the VOC controller, that samples the air on a 
regular basis, will then trigger the second all UVV lamp for a period of 90 seconds. This cycle 
will repeat itself until there is no more smoke in the room: the second lamp will then shut 
off, leaving the first lamp on doing the work 

 
 

SIMPLIFIED PROCESS

:  

 

Ashes in the “white” smoke will be trapped onto the filter

  

 

Nicotine molecules will be dried by the UVC rays than trapped in the filters without the tar like 
material that coats everything. 

 

VOC will be oxidised by the UVV, reducing substantially their olfactory perception.

 

 

It is very important that the fan processes the air rapidly.  

 

 

Changing the filters regularly is a must. 

Summary of Contents for S300 VOC

Page 1: ...ield o One 1 VOC controller part MSC1A factory s pre set Two 2 replacement pre filters part MSCFTR10 LAMP INSTALLATION 1 Remove the 6 screws on the front cover The one with the SANUVOX logo Put aside 2 Remove the BLUE END CAP lamp from packaging Use the gloves provided 3 Insert the lamp in the second clamp and tighten furthest clamp from opening 4 Holding the cap with one hand plug the white conne...

Page 2: ...u can replace it with BX cable with 3 wires WORKING INSTRUCTION The VOC controller analyzes the air every 90 seconds A 20 foot wire set connects it via a relay to activate the second oxidizing lamp on demand The S300 unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However when the cigarette smoke in...

Page 3: ...REEN LED will turn solid Either blow cigarette smoke or propane gas into the controller the RED LED lights up and the relay will trigger on the oxidizing lamp all UVV This sequence reproduce itself every minute or so When there is no more smoke VOC the RED LED will turn off at the same time as the lamp Screw back the cover of the controller When the unit is powered the GREEN LED on the cover will ...

Page 4: ...ired concentration for the specific Volatile Organic Compound being sensed Note The value ofR8 can be changed to vary the range of the sensor A lower value decreases sensitivity increases range and a higher value increases sensitivity decreases range 6 2 red LEDs Led Lo D3 and Led Hi D2 are used to indicate the relay condition a Led Lo is ON when Relay Lo is ON and OFF when Relay Lo goes OFF b The...

Page 5: ...ects it via a relay to the device to activate the second oxidizing lamp on demand The S300 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However if there is much smoke in the room the VOC controller that samples the air on a regular basis will then trigger the second all UVV lamp for a period ...