ULTRAVIOLETS: UVV & UVC
The UVC (254 nm) and UVV (185 nm) light produced by Sanuvox UV units and systems are the same two UV wavelengths
produced by the Sun. The UVC wavelength attacks the micro-organisms on a molecular level deactivating and destroying the
contaminants, while the UVV wavelength degrades the chemicals and odors. Unlike conventional UV lamps on the market,
Sanuvox UV units and systems use a patented process designed to deliver the maximum UV dosage to the moving air-stream
or surface.
CAUTION: Never expose eyes or skin to ultraviolet light from any source.
STORAGE
The P900-GX does not require specific storage. It is a portable unit that works continuously when ON, or automatically when
selecting proper settings (fan speed and timer).
CAUTION:
Keep away from unsupervised children. This unit is not a toy.
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE
The product is rated at 120V to 240V, and 50 Hz to 60 Hz.
See product label to confirm power consumption of your specific unit or system.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE
PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO
MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
Problem
Possible Cause
Solution
Unit doesn’t come ON.
- There is no power to the electrical
outlet.
- Make sure the power outlet is working.
- Make sure the unit is plugged in to
120V outlet.
- The On/Off switch is not ON.
- Push the ON button on the display.
- The power cord is damaged.
- Replace power cord.
- The micro switch / cut-off switch is not
well engaged.
- Make sure the lamp door is well
closed.
- Make sure the lamp door pin pushes
on the micro switch / cut-off switch.
Unit comes ON, but
lamp is OFF: its
“glow” isn’t visible throught the oulet
louver.
- Lamp and/or ballast are defective.
- Get a genuine replacement lamp and/
or ballast.
- Replace lamp and/or ballast.
Unit comes ON and lamp is ON, but
the motor is not turning or is making
rattling noise.
- Motor is defective.
- Replace motor.
- Motor wire connection is not properly
connected.
- Check motor wire connection.
See Verification of Motor Wire
Connection instructions on page 11 (A)
.
Contact your contractor for all your needs in terms of replacement parts:
power cord, control panel display, UV lamp, ballast, filter, grill, fan motor, stand, handle, etc.
TROUBLESHOOTING
If your product is not working properly, refer to the following.
What you will need