7
Instruction Manual for P900-GX
1-888-726-8869
www.sanuvox.com
How to Adjust Fan Speed
1. While the P900-GX is powered ON, press the “Mode Button” to switch between settings. When “Fan Speed LED Indicator”
flashes, numeric digits on the “LED Display Window” corresponds to the unit fan speed.
2. Use the up and down arrow buttons to select fan speed.
Variable fan speeds can be set between 1 to 9 (low-high).
MAINTENANCE
How to Replace Lamp(s)
Replacing lamp on the P900-GX is quick and easy. Simply turn off the power source, remove and dispose of old lamp, replace
with new Sanuvox branded UV lamp, turn power source back on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.
Step by Step Lamp Replacement
1. Unplug P900-GX from wall outlet.
Turn face down and place on soft surface to protect top of unit.
CAUTION:
Before installing or performing maintenance on the unit or
system, TURN OFF AND DISCONNECT the unit or system from all
power sources.
2. Remove the 4 screws from the lamp access door. Then remove lamp
access door.
NOTE:
There is a micro switch / cut-off switch to cut power to the
P900-GX when the lamp access door is removed.
4. Press the lamp clamp to release the old lamp, and slowly remove the
old lamp.
3. Once the lamp access door is removed hold the old lamp by the ceramic
socket and remove the white plug from the old lamp.
STEP 1
STEP 2
STEP 4
STEP 3