INSTALLATION - continued
To Mount
Refer to “
Using the COUPLER to join
multiple 3/4" Support Rods” on the bottom of page 5.
Coupler Tube
: In the event that the unit’s side panels (that support the fixture) are wider than the included Support Rod or the
installation requires multiple
, the Coupler Tube can be inserted between two or more Support Rods or 3/4 EMT
conduit allowing the Support Rods to be extended to desired lengths. Refer to “
Using the COUPLER to join multiple 3/4"
Support Rods” on the bottom of page 5.
To Mount the Aluminum Reflector to the Support Rod
6. Attach the clamps to the back of the Aluminum Reflector using the supplied phillips screws and lock washer.
The holes in the Parabolic Reflector are pre-drilled.
7. a) Attach the Parabolic Reflector to the Support Rod tightening the clamp securing the assembly in place.
b) While wearing the included cotton gloves, carefully “clip” the UV Lamp using the metal spring clips into the
Parabolic Reflector. NOTE: For ease of operation, the Lamp end with the four pins should be pointing in the direction of the
Ballast Box.
Limit Switch Installation
8. To protect users from direct exposure to the ultraviolet rays, a Limit Switch may be field supplied. The Limit Switch will shut down
operation to the UV system should the access door be opened. A Limit Switch is available from Sanuvox (part# MSCSWC14).
3/4" Support Rod to the Mounting Flanges
4. Insert the 3/4" Support Rod into the two Mounting Flanges and tighten the two phillips screws on
either mounting flange.If using more than one
fixture, multiple Support Rods may
be joined together by using the included Coupler.
5. The
is to be installed with the UV Lamp facing the conveyor. The Mounting Flanges attach
directly to the unit’s side panel.
-
FoodSafe IL
FoodSafe IL
FoodSafe ILs
The UV Lamp end with the four
pins should be pointing in the
direction of the Ballast Box.
4