background image

SPEED

RESET

TIMER

UV/ION

POWER

6

Instruction Manual for Biopür

1-888-726-8869

www.sanuvox.com

OPERATION

How to Operate your Product

The Biopür is a easy-to-use unit: once it’s installed and plugged in, simply press the power button to turn it ON and adjust 

funtions to your needs.

 CAUTION:

 The suggested operating temperature range is 10 to 50°C (50 to 122°F). Operating the Biopür outside this range 

will result in decreased performance. For optimal performance, air temperature moving through the reaction chamber should be 

in the range of 15 to 20°C (60 to 70°F).

How to Read the LCD Screen Display

The Biopür LCD Screen Display will give you real time status update about your unit and its lamp.

In “Default Mode” ( power is ON and unit operates normally); the Biopür lamp is always lit, the Fan Speed is at II, the Timer is 

turned off, both UV and ION function are on.

Power Button

Turning the unit ON or OFF

Speed Button

Toggling between fan speeds

 

I, II, III and AUTO

Reset Button

Reseting the unit

HEPA Indicator

Indicating when filters need to 

be changed or cleaned

AUTO Indicator

Indicating when the automatic 

function is activated

FAN SPEED Indicator

Indicating fan speed:

 Low (650±100RPM) 

II 

Medium (1000±100RPM)

III 

High (1250±100RPM)

UV Indicator

Indicating the UV function 

is activated

TIMER Indicator

Indicating the TIMER function

 

is activated and showing time left

ION Indicator

Indicating the ION function

 

is activated

Remote Control

The unit comes with an infrared remote control.

 

To use the remote control, point the remote in the direction

 

of the LCD Screen Display.

API Indicator

(Air Pollution Index)

Visually indicating the air 

quality in the room

Timer Button

Toggling between timer settings

 

1Hr, 2Hr, 4Hr, 6Hr, 8Hr and CANCEL

UV/ION Button

Toggling between UV, ION or 

both functions

Summary of Contents for BIOPUR

Page 1: ...orm to these at his own expense 5 Follow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnec...

Page 2: ...hat s included 4 Step by Step Setup Installation 4 OPERATION 6 How to Operate your Product 6 How to Read the LCD Screen Display 6 MAINTENANCE 7 How to Replace Lamp and Filter Kit 7 Step by Step Lamp Replacement 7 Step by Step Filter Kit Replacement 8 How to Clean your Product 9 STORAGE 9 ULTRAVIOLETS UVV UVC 9 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 9 TROUBLESHOOTING 9 Problems Solu...

Page 3: ...a series of filters then into the reaction chamber so that the air travels parallel to the UV lamp where a germicidal and oxidizing process destroys biological and chemical contaminants A Remote Control B LCD Screen Display C Lamp Chamber D Plastic Cover E Inside Filter Kit F 2 6m Power Cord with a AC120V Two Flat Plug Type ACCESSORIES KITS The following accessories and or kits work great with you...

Page 4: ...system label If you have any questions regarding the installation instructions call SANUVOX at 1 888 726 8869 What s included The Biopür a remote a UV lamp with its reflector a TiO2 catalyst and a filter kit The filter kit includes a prefilter a HEPA filter and an activated carbon filter Step by Step Setup Installation 1 Prepare the Biopür for installation Remove contents from packaging 2 Remove t...

Page 5: ...yst b Activated Carbon Filter c HEPA Filter d Prefilter CAUTION Never turn your unit on with filters still wrapped This may cause damage to your unit STEP 3 STEP 4 STEP 5 STEP 6 5 Once unwrapped filters are placed back inside the unit turn latch to keep filters in place 6 Securely replace the unit cover First fit the top of the unit into place and slowly press the bottom as to allow the bottom cli...

Page 6: ...ed is at II the Timer is turned off both UV and ION function are on Power Button Turning the unit ON or OFF Speed Button Toggling between fan speeds I II III and AUTO Reset Button Reseting the unit HEPA Indicator Indicating when filters need to be changed or cleaned AUTO Indicator Indicating when the automatic function is activated FAN SPEED Indicator Indicating fan speed I Low 650 100RPM II Mediu...

Page 7: ...e unit lift the cover upwards 5 Carefully slide the new UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included with the lamp guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negatively impact the UV output of the lamp 2 Once the Biopür is open you will see the locking latch inside the Biopür at the top Twist latch to allow the filters to be r...

Page 8: ...t turn latch to keep filters in place 9 Securely replace the cover To replace the unit front cover first fit the top of the unit into place and slowly press the bottom as to allow the bottom clips to catch Now you can plug in and turn on your Biopür STEP 6 STEP 7 STEP 8 STEP 9 Step by Step Filter Kit Replacement 1 Turn off and unplug your Biopür Remove the unit cover To remove the front cover gras...

Page 9: ... AC120V 60Hz See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONA...

Page 10: ...ct from the original date of purchase B At its option SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included excep...