1.0 IMPORTANT INSTALLATION POINTS

1.1

 

 The Aquaheat unvented water heater MUST be fitted with a Pressure (Expansion) 

Relief Valve. This MUST be fitted to the cold water supply near the heater. 

  

       FAILURE TO PROVIDE  ADEQUATE  PRESSURE  RELIEF  WILL  

INVALIDATE  ANY GUARANTEE  AND  LEAD  TO  A  DANGEROUS  
INSTALLATION

1.2

  Expansion can take place within the cold water supply 

PROVIDED  THAT  

BOTH

 :

 

(a) Backflow in the main is not prevented by any stopvalve with loose jumper, 

check valve, pressure reducing valve or similar, 

AND

 

(b) Hot water expansion 

does not

 enter a branch to a cold water outlet 

             (see Figure 1 for expansion pipe lengths).

 

N.B. Both the above conditions must be met. Additionally expansion within 

the cold water supply will not be possible if the static supply pressure exceeds 

4.1 bar (60p.s.i.).

1.3

  If any of the conditions in 1.2 above cannot be met expansion must be accomodat-

ed using an Expansion Vessel. To ensure all expansion takes place in the vessel a 

Non Rerturn Valve 

must

 also be fitted together with a Pressure (Expansion) Relief 

Valve (see Figure 2). Use Accessory Pack ALK05 (94970012).

1.4

  If the static supply pressure exceeds 4.1 bar (60p.s.i.) a Pressure Reducing Valve  

must be fitted to the cold main supply. If a Pressure Reducing Valve is used an 

Expansion Vessel must also be used (see Figure 3). Use Accesories Pack ALK04 

(94970011).

1.5

 Where specifications demand the fitting of a Temperature/Pressure Relief Valve, 

one can be fitted on site (see Figure 4). Use Accesory Pack ALK06 (94970013). 

Note the fitting of ALK06 does not alter the requirements detailed in points 1.1 to 

1.4 above.

WARNING: IF  WATER  FLOWS  FROM  THE  PRESSURE  RELIEF  VALVE 

OR TEMPERATURE / PRESSURE RELIEF  VALVE (IF  FITTED) THE ELEC-

TRICITY SUPPLY  MUST BE SWITCHED OFF  IMMEDIATELY. CONTACT  

THE  SANTON SERVICE TEAM (TEL: 01603 420347) OR AN APPROVED 

INSTALLER.

3

Summary of Contents for AH10/2.2

Page 1: ...read and understand these instructions before starting work Please leave this leaflet with the user following installation PACK CONTENTS Heater Pressure relief valve Fixing screws and plugs Installation and User Instructions WARNING This water heater must only be installed by qualified persons 36005791 Issue 3 ...

Page 2: ...W 15l 2 2kW Storage volume V litres 7 0 10 0 15 0 Mixed water 40 C V40 l 13 17 25 Load Profile XXS XXS XXS Energy Efficiency Class C C C Energy Efficiency 31 3 30 6 30 8 Annual electricity consumption kWh 589 603 599 Daily fuel consumption kWh 2 860 2 940 2 920 Thermostat setting 60 C Specific precautions that shall be taken when the water heater is assembled installed or maintained and disposed o...

Page 3: ...ditions in 1 2 above cannot be met expansion must be accomodat ed using an Expansion Vessel To ensure all expansion takes place in the vessel a Non Rerturn Valve must also be fitted together with a Pressure Expansion Relief Valve see Figure 2 Use Accessory Pack ALK05 94970012 1 4 If the static supply pressure exceeds 4 1 bar 60p s i a Pressure Reducing Valve must be fitted to the cold main supply ...

Page 4: ...T COLD DRAW OFF SERVICE VALVE COLD WATER MAINS 2 0 7L 2 8 10L OR 4 2 15L METRES IS REQUIRED FOR EXPANSION IN PIPEWORK FIGURE 1 FOR INLET WATER PRESSURES UP TO 4 1 BAR 60 P S I NO ADDITIONAL KITS USED COLD EXPANSION VESSEL NON RETURN VALVE NEAREST COLD DRAW OFF SERVICE VALVE COLD WATER MAINS FIGURE 2 FOR INLET WATER PRESSURES UP TO 4 1 BAR 60 P S I WHERE EXPANSION IN MAIN SUPPLY IS NOT POSSIBLE USI...

Page 5: ...ricity gas or water below the surface of the wall 2 5 DO NOT install where the unit may freeze 2 6 Refer to the section IMPORTANT INSTALLATION POINTS to determine which valves and accessories are required Plumb in the valves in the sequence shown in the relevant Diagrams Figures 1 2 and 3 2 7 Both inlet and outlet pipes are clearly labeled The pipes are 15mm copper tube and are suitable for compre...

Page 6: ...CT 3 0 INSTALLATION ELECTRICAL REQUIREMENTS WARNING This appliance must be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations 3 1 The unit is supplied fitted with a 0 75m 3 core 1 5mm2 flexible cable The electic ity supply should be fused 13 Amp and be via a doub...

Page 7: ...n met 5 3 Check that all water and electrical connections are tight 5 4 Open a hot water tap turn on mains water supply to the heater 5 5 Allow unit to fill and leave hot tap running for a short while to purge any air and flush out the pipework Close the hot tap and check the system for leaks 5 6 Manually test the operation of the Pressure Expansion Relief Valve and if fitted the Temperature Press...

Page 8: ... unit through the outlet connection 7 3 Remove the terminal cover as described in Section Six 7 4 Disconnect the electrical terminations to the thermostat Disconnect earth links to the earthing stud 7 5 Remove the element plate assembly by unscrewing the five securing screws tapped jacking points are provided Remove any loose scale from the container Carefully clean off any scale from the element ...

Page 9: ...re 95 614 274 Terminal cover 15 litre 95 614 275 8 0 MAINTENANCE SAFETY VALVES The Pressure Expansion Relief Valve and if fitted the Temperature Pressure Relief Valve should be regularly checked Manually operate the valves by either twisting the cap or lifting the lever Ensure water flows freely from the valve s and through the discharge pipes Ensure the valve s reseat correctly when released 9 0 ...

Page 10: ... intermittently Presure Relief Valve Discharge of water from 1 Fit pack ALK05 94970012 see IMPORTANT INSTALLATION POINTS 2 Fit pack ALK04 94970011 see IMPORTANT INSTALLATION POINTS 3 Replace Pressure Relief Valve 4 Check and if necessary re charge Expansion Vessel pre charge pressure see Section 9 0 1 Expansion in mains not possible 2 Mains pressure exceeds 4 1 bar 60 p s i 3 Pressure Relief Valve...

Page 11: ... of freezing when the heater is not in use for long periods during the winter months do not switch off the electrical supply and set the thermostat to its minimum position N B This will not protect other system pipework 13 2 The indicator light will be illuminated when the unit is heating 13 3 To ensure the heater continues to operate at its optimum performance it should be periodically maintained...

Page 12: ...e unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner container with integral immersion heater is not guaranteed against excessive scale build up This Guarantee in no way affects the statutory rights of the consumer The policy of Santon is one of continuous product development and as such we reserve the right to change specifications w...

Reviews: