Figure 42: Serial link terminal board
Terminal
board
Position
Function
DC.X11
1
(TX/RX A) Differential input/output A (bidirectional) according to the
RS-485 standard. Positive polarity in respect to pin 2 for one MARK. D1
signal according to the nomenclature from the MODBUS-IDA
association.
2
(TX/RX B) Differential input/output B (bidirectional) according to the
RS-485 standard. Negative polarity in respect to pin 1 for one MARK.
D0 signal according to the nomenclature from the MODBUS-IDA
association.
3
0V(GND) serial link zero volt
. “Common” according to the MODBUS-
IDA association.
4
Shield.
For details related to communications please refer to section
Error! Reference source not found.
.
NOTES
The serial link zero volt is isolated both in respect to the environmental signal 0V and the digital
signal 0V.
6.8.