Bedienungsanleitung / User manual
VTC-8100P / VTC-8112P / VTC-8200P / VTC-8212P / VTC-8300WDP / VTC-8312WDP
_________________________________________________________________________________
- 40 -
a. G-sensor function „detection“
The detection function of the G-sensor is activated by setting the sensitivity from 2-9.
Creep:
Reaction of camera movement towards slight position changes (horizontally or
vertically).
The sensitivity level (2-9) can be defined for the detection function of the G-sensor
(the electronic water level doesn’t have sensitivity features):
0 =
G-sensor is completely turned off (detection function and water level)
1 =
water level is activated (and detection is deactivated)
2 =
very low sensitivity (for outdoor applications; standard security level;
very rough outdoor conditions)
3 =
mid-low sensitivity (for outdoor applications; standard security level;
rough outdoor conditions)
4 =
low sensitivity (for outdoor applications; standard security level;
normal outdoor conditions)
5 =
mid-B sensitivity (for outdoor applications; high security level;
normal outdoor conditions)
6 =
mid-A sensitivity (for indoor applications; low standard security level)
7 =
high sensitivity (for indoor applications; standard security level)
8 =
mid-high sensitivity (for indoor applications; high security level)
9 =
very high sensitivity (for indoor applications; highest security level)
Impact:
Reaction towards e.g. a hit onto the camera (sabotage)
Duration:
Duration of the display in the picture:
camera moved
motion
camera movedt <S>
impact
The output contact on the backside of the camera is closed for the programmed time.
Duration steps:
5 sec, 10 sec, 15 sec, 30 sec,
1 min, 2 min, 5 min, 10 min, 20 min, 30 min
Light:
see description on page 37
Exit/Save:
The desired adjustments and value are saved.