PLEASE READ THIS USER MANUAL AND THE SAFETY INSTRUCTIONS BE-
FORE  INSTALLING THE UNIT AND STARTING IT UP!

Transport

Please transport the UPS system only in the original packaging (to protect against
shock and impact).

Set-up

Condensation may occur if the UPS system is moved directly from a cold to a
warm environment. The UPS system must be absolutely dry before being installed.
Please allow an acclimatization time of at least two hours.

Do not install the UPS system near water or in damp environment.

Do not install the UPS system where it would be exposed to direct sunlight or near
heat.

Do not block air vents in the front, in the back or on the sides of the UPS.

Installation

Do not connect appliances or items of equipment which would overload the UPS
system (e.g. laser printers) to the UPS outlet socket.

Place cables in such a way that no one can step on or trip over them.

Do not connect household appliances such as hair dryers to the UPS output
sockets.

The UPS can be operated by any individuals with no previous training.

       Following for 1K(S)/2K(S)/3K(S) only

Connect the UPS system only to an earthed shockproof socket outlet.

The utility power socket-outlet (shockproof socket-outlet) must be easily
accessible and close to the UPS system.

During  the installation of this equipment it should be assured that the sum of the
leakage current of the UPS and the connected loads does not exceed 3.5mA.

       Following for 6K only

Warning 

- This is a product for designated sales distribution to authorized partners.

Installation  or additional measures should be carried out by qualitied personal  to
prevent disturbances.

A readily accessible disconnection device shall be incorporated in the building
installation wiring and the disconnection device must be easily accessible and
close to the UPS system.

Only qualified maintenance personnel may carry out installations.

Summary of Contents for C1KR(S)

Page 1: ...USER MANUAL RACK MOUNT 1 2 3 6kVA...

Page 2: ...ance 7 4 1 Operation Environment 7 4 2 Battery Application 7 4 3 Troubleshooting 7 5 Technical Data 9 5 1 Electrical Specification 9 5 2 Typical Stored Energy Time 9 5 3 Mechanical Data 9 5 4 Standard...

Page 3: ...y for fileservers minicomputers Internet hubs telecommunication systems and other mission critical applications It can auto restart while AC source restored after discharge shutdown and it also can su...

Page 4: ...es in such a way that no one can step on or trip over them Do not connect household appliances such as hair dryers to the UPS output sockets The UPS can be operated by any individuals with no previous...

Page 5: ...ries No other persons should handle the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals a...

Page 6: ...ity of the live conductor L and the neutral conductor N of site wiring reversed UPS ON LED Lights up when output power is supplied by the mains power via the inverter BATTERY LED Lights up when the ma...

Page 7: ...f the UPS and the battery packs are shown as below INDICATOR 1 5 Shows the load level in utility power mode Shows the battery level in battery mode 1K S Only available for 1KS Output socket Intelligen...

Page 8: ...k for 6K Intelligent Output Surge Input External battery Output Communicationport Output Input 2KS 3K S Output fuse Output socket Input breaker Intelligent slot Input output terminal External battery...

Page 9: ...together to achieve desired run time Notes It is suggested that one battery pack can be connected with one UPS main unit Only the identical battery packs can be connected in parallel to the models wi...

Page 10: ...the polarity of site wiring or building wiring AC INPUT LED blinks and BATTERY LED lights up Input power and or frequency are out of tolerance The UPS is now running in battery mode To save your data...

Page 11: ...MODE Notes Backup time of S models please consult the distributor Typical values at 25 C in minutes Model C1KR C1KRS C2KR C2KRS C3KR C3KRS C6KR INPUT Voltage 220VAC Frequency 46 Hz 54 Hz Adjustable Am...

Page 12: ...8 bits Ending Bit 1 bit Parity Bit none 1K S 2K S 3K S Conducted Emission EN50091 2 Class B Radiated Emission EN50091 2 Class B Harmonic Current EN61000 3 2 Voltage Fluctuations and Flicker EN61000 3...

Page 13: ...ion of DB 9 connector in AS400 card 5 TECHNICAL DATA 5 5 1 RS232 INTERFACE The following is the pin assignment and description of DB 9 connector Pin Description I O 2 RS232Tx Output 3 RS232 Rx Input 5...