Figure 3.6.4.1
Currently, the system only supports and communicates with smart-UPS of APC (American Power
Conversion Corp.) UPS. Please review the details from the website:
http://www.apc.com/
.
First, connect the system and APC UPS via RS-232 for communication. Then set up the shutdown
values when power is failed. UPS in other companies can work well, but they have no such
communication feature.
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None for other vendors or no
UPS.
Shutdown
Battery Level (%)
When below the setting level, system will shutdown. Setting level to
“0”
will
disable UPS.
Shutdown
Delay (s)
If power failure occurred, and system can not return to value setting status, the
system will shutdown. Setting delay to
“0”
will disable the function.
Shutdown UPS
Select ON, when power is gone, UPS will shutdown by itself after the system
shutdown successfully. After power comes back, UPS will start working and notify
system to boot up. OFF will not.
Status
The status of UPS.
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”
“UPS shutdown in progress”
“Batteries failed. Please change them NOW!”
Battery Level (%)
Current percentage of battery level.
3.7 System maintenance
“Maintenance”
allows operation of the system functions including
“Upgrade”
to the latest firmware,
“Info”
to show the system version,
“Reset to default”
to reset all controller configuration values to
factory settings,
“Config import & export”
to import and export all controller configuration except VG/
UDV setting and LUN setting, and
“Shutdown”
to either reboot or shutdown the system.