4.07 Internal Parameter Selection
Internal parameters can be set by pressing and holding the encoder button.
Turn the encoder to display “End” and press the encoder to return to the standby screen.
Code No.
Items
Setting area
Default
Remarks
P00
Anti-Stick
OFF / ON
OFF
[ON Setting]
The welding current is reduced to 25A
if the output short-circuit state continues
for 1 second or longer in stick mode.
P14
Setting the maximum
peak current at
REMOTE
OFF / ON
OFF
[OFF Setting]
The welding current set on the operation
panel is the maximum current.
[ON Setting]
Maximum current is 300A.
P19
2T Slope Function
OFF / ON
OFF
See Section 6.6.1
P20
4TS mode Setting
OFF / ON
OFF
See Section 6.6.2
P24
AC waveform
Selection
OFF / ON
OFF
[OFF Setting]
Sinusoidal wave
[ON Setting]
Triangular wave
P26
OK to Move current
detect signal output
logic inversion
OFF / ON
OFF
[OFF Setting]
CON1_M-N short-circuited at current
detection.
[ON Setting]
CON1_M-N is open when current is
detected.
P31
Operation panel lock
password setting
OFF / ON
OFF
When the encoder button and mode
selection button are pressed at the same
time, the panel is locked and parameter
changes are prohibited.
[OFF Setting]
The panel lock is released by pressing the
encoder button and mode selection button
at the same time.
[ON Setting]
When P31 is turned on, a password for
unlocking the panel can be set.
When releasing the panel lock, the panel
lock can be released by setting the
password set in P31.
Summary of Contents for IA-3000TP-U3E
Page 2: ......
Page 4: ......
Page 8: ......
Page 26: ...26 PAGE LEFT INTENTIONALLY BLANK ...
Page 32: ...32 PAGE LEFT INTENTIONALLY BLANK ...
Page 54: ...54 PAGE LEFT INTENTIONALLY BLANK ...
Page 74: ...74 PAGE LEFT INTENTIONALLY BLANK ...
Page 87: ...87 PAGE LEFT INTENTIONALLY BLANK ...
Page 94: ...PAGE LEFT INTENTIONALLY BLANK ...
Page 97: ...PAGE LEFT INTENTIONALLY BLANK ...