7. CONNECTIONS
WARNING: machine connecting
operations must be performed by a
specialised and authorized techni-
cian.
7.1 - WATER CONNECTION
•
The machine is supplied with the water intake and
drain pipes already connected.
Drain
A water drain (1) with siphon must be prepared near
the machine.
The drain siphon must be posi-
tioned at least 20 cm below the area
the machine is standing on.
•
Connect the free end (2) of the drain pipe to the drain
siphon (3) previously prepared, checking that the
drain pipe is free, without kinking or obstructions.
Intake
The machine must be connected to
a water mains supplying
drinking
water, softened to a maximum hard
-
ness of 3.5/5 French degrees (60/85
ppn).
Check that the supply pressure
does not exceed 4 bar (0.4 MPa). If
pressure is greater, install a pres
-
sure reducer
.
•
Connect the intake pipe (4) to a softener (5) with
the supplied impurity filter (6) between them
•
Before the softener (8), install a shuttering tap to
separate the water system from the machine.
. .
To install, operate and service the
softener, see the relevant instruc
-
tion manual.