Analysis of common problems
Phenomenons
Causes
It may be that the machine runs
too long, or the ambient temperature
is too high, resulting in the machine's
motor temperature being too high;
the machine starts the overheating
protection program, automatic
shutdown.
Solutions
The machine suddenly
stops working during use.
Speed reset to "0", unplug the power,
wait for the machine to return to room
temperature and then it can be
restarted (generally need 15-30
minutes, the room temperature
varies cooling time).
Check if the plug is in good contact
with the socket.
Turning the speed knob
but machine does not run.
Verify that the power plug is plugged
into the outlet.
Check if the power is out.
Check if the lifting knob spring
back in place.
Wait for power before operating
Make sure the headstock is stuck
in place.
Excessive noise when the
machine is running
1.The machine will work louder in
high gear than in low gear.
2.The amount of food stirred is too
large, resulting in overloading the
machine.
3.Voltage is unstable.
4.Working time is too long.
1. Choose the right speed to stir food
according to the recommendations
in the manual
2. Reduce the amount of stirring.
3.If the voltage is unstable, wait for
the voltage to stabilize before using.
4.If the working time is too long, stop
and cool down for a while
before using.
The machine speed
drops, or the speed
is unstable
1.Whether the room temperature is
low, causing the lubricant in the
machine to harden.
2.The ingredients stirred are too
hard and too much, resulting in too
much load on the machine.
3.Whether the voltage suddenly
becomes low.
1.
Remove the mixing bowl and let
the machine idle for 5 minutes to
soften the lubricant in the machine
and restore the speed stability.
2.
Reduce the mixing volume and
let the machine work according to
the normal workload.
3.
When the voltage is stable, use
the machine again.
Machine swaying and
shaking when working
1.Check if the foot pad on the base
is off.
2.Whether the machine is placed
on a smooth and flat countertop
for use.
1.Check if the foot pad on the base
is off.
2.Place on a smooth and flat
countertop for use
9