16
MITSUBISHI inverter FREQROL D700 standard specifications
Applied motor
90W
Rated output voltage
AC 200V three-phase
Power source voltage
Type 710W: AC 100V single-phase
720S : AC 200V single-phase
720 : AC 200V three-phase
Permissible voltage variation
100V: 90-132V
200V: 170-264V
Power source frequency
50/60Hz
±
5
%
Environmental
conditions
Temperature -
10℃ to +40℃
(Avoid freezing)
Humidity
RH 90% or less (Avoid condensation)
Atmosphere
Indoor, no corrosive/flammable gases,
no oil mist or dust
Elevation
1,000 m or less above sea level
Vibration
5.9 m/s
2
or less
■
Caution When Using Inverter
CAUTION
1. Be sure to confirm that the power source voltage is within the rated voltage
range, before switching ON the power source. (Voltage exceeding the rated
voltage could cause fuming, abnormal noise, etc.)
2. Be sure to start and stop the conveyor with RUN/STOP switch. When starting
and stopping the conveyor frequently in a short period (tact operation etc.), it is
impossible to start/stop the machine by turning on/off the power supply. In this
case be sure to start and stop the machine by external signals. (Inverter
variable-
speed type is different from speed controller’s, and the power supply
will trip.) Do not start and stop the conveyor excessively frequently. It may cause
machine failure or shorten its service life.
3. The RUN/STOP switch of inverter unit is not for turning the power on and off.
When leaving the conveyor unused for a long period, make sure that the mains
is off.
4. Do not run the conveyor at excessively low speed for a long period, or start and
stop the conveyor excessively frequently. These may cause machine failure or
shorten its service life.
5. Do not touch the inverter radiator of side of inverter unit, and do not allow any
material to touch it, because of its high temperature.
6. Use the inverter unit within the permissible range of ambient temperature (from
–10℃ to +40℃). Avoid freezing.
7. Pay special attention not to allow any foreign matter (dust, iron powder, etc.) to
get into the inverter unit.
8. Operating the motor using the inverter could cause noises from the inverter I/O
cables, motor, etc. Keep in mind that these could interfere with the correct
operation of other electronic devices. (In this case, noises and their effects can
be suppressed to some extent by providing the inverter I/O with a filter or
otherwise shielding the power cable.)