Electromagnetic Feeder Controller 

 

Instruction Manual 

 

 

St Feedback Type

 

MFC-S3B-F

 

MFC-S6B-F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This  Instruction  Manual  is  applicable  to 
Electromagnetic Feeder Controller version 
1 and later. 
Confirm  the  version  information  displayed 
upon powering ON.

 

Read the Manual carefully beforehand to ensure the safe use of the Controller. 
After reading, store the Manual within reach so as to be ready for rereading. 
The dealer is requested to be sure to deliver the Manual to the end user.

 

Summary of Contents for MFC-S3B-F

Page 1: ...etic Feeder Controller version 1 and later Confirm the version information displayed upon powering ON Read the Manual carefully beforehand to ensure the safe use of the Controller After reading store...

Page 2: ......

Page 3: ...ration for Operation Operation and Amplitude Adjustment Method Added Function 9 1 Soft start and soft stop functions 9 2 Overflow Sensor Timer Function 9 3 Operation Signal Delay Output Timer Function...

Page 4: ...parts feeder 2 Before Using Before unpacking be careful not to have an impact or vibration on the packing Unpack and check the following 1 Isn t there any damage caused during transport 2 Are the rat...

Page 5: ...le or the output cable or an electric shock or a fire could be caused Ground the earth terminal and the ground prescribed portions without fail or an electric shock could be caused When working on gro...

Page 6: ...nel fixing screw 2 locations When attaching detaching the operation panel carefully watch out for disconnection pinching etc Overflow sensor input cable P3 cord 0 1m Power Output terminal block Operat...

Page 7: ...detach the flat blade screwdriver to release the button and the wire will be fixed Applicable wire size Terminal block A S Stranded wire AWG26 20 Solid wire AWG26 20 Wire strip length 10 11mm Terminal...

Page 8: ...gnal Solenoid valve etc Parameter setting Amplitude control in1 and in2 input logic Amplitude adjustment Constant voltage mode 0u 0 Constant amplitude mode 0u 1 Feedback adjustment Added function Set...

Page 9: ...nput power supply side 3 Vibration sensor connection Connect the vibration sensor to perform constant amplitude control 1 Mounting of vibration sensor Fix the vibration sensor Accessory onto the top o...

Page 10: ...edicated cable of our make In wiring each cable detach the wiring from the power cable 4 Overflow sensor in2 input connection Connect the overflow sensor to the terminal of the overflow sensor input c...

Page 11: ...ternal control terminal block by using the method or below while watching out for the signal to be used and the connection method When wiring be careful not to make mistake about the polarity The curr...

Page 12: ...and OFF rises behind the feeder output 4 Alarm signal error signal output out2 Relay contact output 250VAC 3A When the parameter is set to Parameter No 08 the function can be switched to the parts sh...

Page 13: ...itude is adjusted in the n mode When the Func key is pressed 3 times the PAT lamp blinks displaying out1 Each time the Freq key is pressed the display changes in order of P1 P2 P3 P4 out1 When the Fre...

Page 14: ...troller is at a forced stop by the ON OFF key Parameter mode pilot lamp ON The parameter setting is in process Blinking The speed magnification change setting is in process only for 0u 1 in the A mode...

Page 15: ...ode Adjusts the frequency Function setting is in display Each function setting can be changed Parameter mode Changes the parameter data G Freq key Long pressing Continually press the key for 2 sec 7 2...

Page 16: ...layed If the process is brought forward to the next item by pressing the Func key without pressing the Set key during the setting change the setting will not be changed If there is no key operation fo...

Page 17: ...the voltage setting uLoc Unlocks The speed magnification can be changed Displays the value of the decimal places of the voltage setting 7 4 Preparation for Operation Before powering ON the Controller...

Page 18: ...oes out and the mode is switched to the adjustment mode Adjustment mode In this mode the frequency and the output can be adjusted and all parameters can be set and changed Data display area Frequency...

Page 19: ...e parameter mode screen appears When the Set key is pressed after value setting the set value is saved If the Vol keys are pressed without pressing the Set key in the change process the changes will n...

Page 20: ...ys If the voltage is too high or too low change the voltage For the distinction between the full wave and the half wave confirm the model etc of the drive In the case of half wave set the frequency to...

Page 21: ...operation is performed based on the value saved in the adjustment mode When u 1 the feedback control is performed Magnification change for vibration quantity can be adjusted Refer to C When 0u 0 Now t...

Page 22: ...er the value is the faster the reaction is If the start is slow If the slow start is not improved even if the number of seconds of the parameter No 0C soft start is made smaller raise the value of the...

Page 23: ...ils the parts feeding speed varies according to the parts quantity This operation raises lowers the amplification rate of the vibration sensor signal input Press the Func key long for 2 sec Press the...

Page 24: ...n proportion to the magnification This function is valid only when the setting is made to the parameter No 0u 1 Be sure to perform the SAVE operation when the feeder is in operation C Fine adjustment...

Page 25: ...Signal Delay Output Timer Function The motion of the operation signal delay output OUT3 can be delayed from the timing of the feeder output Parameter No 0E Start delay The time until the OUT3 becomes...

Page 26: ...h the Vol key and the Freq key together 2 The data display area displays io01 to start the Controller If the Controller starts in a normal manner redo the above 1 and 2 3 Press the Freq key to select...

Page 27: ...emote control The frequency to be used for remote control is the set frequency of the main unit of the controller For details of usage of the remote unit refer to the instruction manual of Remote Unit...

Page 28: ...ey in the change process the changes will not be saved but cancelled If there is no key operation for over 5 min the normal mode screen voltage display will be forced to reappear When the Set key is p...

Page 29: ...valid oF on oF 0P PI control gain Setting of the speed of output response to vibration change when the constant amplitude control is in process 1 slow 27 fast 1 27 10 06 in1 setting in1 Input logic hi...

Page 30: ...gh E 05 Error of no connection to the vibration sensor The vibration sensor is not connected The drive was operated in A mode with the parameter set to No 0u 1 E 10 Parameter error Memory error on sta...

Page 31: ...oller output cable cover or the feeder wire cover Replace the damaged cable or wire The frequency is deviant Adjust the frequency to the resonance frequency One of the memory errors E 10 12 occurs whe...

Page 32: ...ernal signal contact or 24VDC Overflow sensor input NPN open collector sensor connection enabled Operation signal output No voltage contact and NPN open collector Speed change Operation pattern change...

Page 33: ...31 32 17 Outside Dimensional Drawing The input and output cables are omitted The input and output cables are omitted Vibration sensor Accessory cable 1m...

Page 34: ...y period we shall provide free repair or part replacement 2 However even if it is within the warranty period following cases shall not be covered under our warranty Failure or break caused by a fire a...

Page 35: ......

Page 36: ...ai Office Tel 81 22 263 8345 Fax 81 22 263 8354 Tokyo Office Tel 81 3 3493 6187 Fax 81 3 3493 6195 Nagoya Office Tel 81 52 691 1147 Fax 81 52 692 1915 Osaka Office Tel 81 6 6746 8222 Fax 81 6 6746 822...