10.
“io”
Mode Setting Function
This Controller can switch the control target of the overflow sensor input [in2 Input].
The functions that the “io” mode setting
can perform:
①
Switching of the
“
io
”
mode
②
Initialization of the set data [Reset to the factory setting]
Function
Control target
io01
Controls the feeder output in [in2 Input]. [with overflow stop] (factory setting)
io02
Does not control the feeder output in [in2 Input]. [without overflow stop]
99
Initializes the set data [Resets to the factory setting].
1)
“io” mode switching method
(1)
When the power supply to the Controller is OFF, power ON the Controller by pressing both
the Vol
▲
key and the Freq
▼
key together.
(2)
The data display area displays “io01” to start the Controller.
※
If the Controller starts in a normal manner, redo the above (1) and (2).
(3)
Press the Freq
▲
key to select the
“
io
”
mode to be used.
The display switches
“
io01
”
→
“
io02
”
→
“
99
”
→
“
io01
”
in this order.
When the Freq
▼
key is pressed, the display area switches them in the reverse order.
(4)
Press the Set key long for 2 sec to start the controller in a normal manner in the selected “io”
mode.
For example, when “io02” is selected, “io02” is displayed when the “io” mode is displayed
upon powering ON the controller.
※
The motion in each
“
io
”
mode is identical to the motion shown in the following time chart:
①
When the
“
io
”
mode is
“
io01
”
②
When the
“
io
”
mode is
“
io02
”
Feeder output
When the “io” mode is “
io02
”
, the parameter
Nos. 0E and 0F become invalid.
Feeder output