28103.33

Quasi-Resonant Topology 

Primary Switching Regulators

STR-W6756

• The contents in this document are subject to changes, for improvement and other purposes, without notice. Make sure that this is the 

latest revision of the document before use.

• Application and operation examples described in this document are quoted for the sole purpose of reference for the use of the prod-

ucts herein and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights or 
any other rights of Sanken or any third party which may result from its use.

• Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semicon-

ductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures 
including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device 
failure or malfunction.

• Sanken products listed in this document are designed and intended for the use as components in general purpose electronic equip-

ment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.).

  When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and 

its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), and whenever 
long life expectancy is required even in general purpose electronic equipment or apparatus, please contact your nearest Sanken sales 
representative to discuss, prior to the use of the products herein.

  The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required 

(aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly  prohibited.

• In the case that you use Sanken products or design your products by using Sanken products, the reliability largely depends on the 

degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation range is set by derating the 
load from each rated value or surge voltage or noise is considered for derating in order to assure or improve the reliability. In general, 
derating factors include electric stresses such as electric voltage, electric current, electric power etc., environmental stresses such 
as ambient temperature, humidity etc. and thermal stress caused due to self-heating of semiconductor products. For these stresses, 
instantaneous values, maximum values and minimum values must be taken into consideration.

  In addition, it should be noted that since power devices or IC's including power devices have large self-heating value, the degree of 

derating of junction temperature affects the reliability significantly.

• When using the products specified herein by either (i) combining other products or materials therewith or (ii) physically, chemically 

or otherwise processing or treating the products, please duly consider all possible risks that may result from all such uses in advance 
and proceed therewith at your own responsibility.

• Anti radioactive ray design is not considered for the products listed herein.
• Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of Sanken's distribu-

tion network.

• The contents in this document must not be transcribed or copied without Sanken's written consent.

Summary of Contents for STR-W6756

Page 1: ...ncreaseofoperatingfrequencyatlightoutputload improving system level efficiency over the entire load range Therearetwostandbymodesavailabletoreducetheinputpower under very light load conditions The first is Auto Standby mode which is internally triggered by periodic sensing and the other is a manual standby mode which is executed by clamping the secondary output In general applications the manualst...

Page 2: ...ith latch Maximum on time limit Absolute Maximum Ratings at TA 25 C Parameter Symbol Conditions Rating Unit Drain Current1 IDpeak Single pulse 15 A Maximum Switching Current2 IDmax TA 20 C to 125 C 15 A Single Pulse Avalanche Energy3 EAS Single pulse VDD 99 V L 20 mH ILpeak 6 05 A 400 mJ Input Voltage for Controller MIC VCC 35 V SS OLP Terminal Voltage VSSOLP 0 5 to 6 0 V FB Terminal Inflow Curren...

Page 3: ...igure 1 for MOSFET SOA temperature derating coefficient Figure 1 MOSFET Safe Operating Area Derating Curve Figure 2 MOSFET Safe Operating Area Drain Current versus Voltage at TA 25 C Single Pulse Terminal List Table Number Name Description Functions 1 D Drain MOSFET drain 2 NC Clipped No connection 3 S GND Source ground terminal MOSFET source and ground 4 VCC Power supply terminal Input of power s...

Page 4: ...Thermal Resistance R QJC C W 0 001 0 010 0 100 1 000 10 000 100μ 10μ 10m 1m 100m 1μ Ambient Temperature TA C Power Dissipation P D1 W 0 5 10 15 20 25 30 0 20 40 60 80 100 120 140 160 PD1 1 3 W at TA 25 C Without heatsink With infinite heatsink PD1 29 W at TA 25 C Figure 3 MOSFET Avalanche Energy Derating Curve VDD 99 V L 20 mH IL 3 6 A Figure 4 Transient Thermal Resistance Figure 5 MOSFET Power Di...

Page 5: ...nal Inflow Current Normal Operation IFB ON VFB 1 6 V 600 1000 1400 μA Standby Operation Standby Operation Start Voltage VCC S VCC 0 15 V VFB 1 6 V 10 3 11 1 12 1 V Standby Operation Start Voltage Interval VCC SK VCC SK VCC S VCC OFF 1 10 1 35 1 65 V Standby Non Operation Circuit Current ICC S VCC 10 2 V VFB 1 6 V 20 56 μA FB Terminal Inflow Current Standby Operation IFB S VCC 10 2 V VFB 1 6 V 4 14...

Page 6: ...treatment Ni plating and solder dip Leadform 2003 Weight approximate 2 3 g Dimensions in millimeters Drawing for reference only Branding codes exact appearance at manufacturer discretion 1st line type STR 2nd line subtype W6756 3rd line lot YM DD Where Y is the last digit of the year of manufacture M is the month 1 to 9 O N D DD is the 2 digit date 1 2 3 4 5 6 7 Terminal dimensions at case surface...

Page 7: ...r mounting the products the mounting surface flatness should be 0 05 mm or less Please select suitable screws for the product shape Do not use a flat head machine screw because of the stress to the products Self tapping screws are not recommended When using self tapping screws the screw may enter the hole diagonally not vertically depending on the conditions of hole before threading or the work si...

Page 8: ...ative to discuss prior to the use of the products herein The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required aerospace equipment nuclear power control systems life support systems etc is strictly prohibited In the case that you use Sanken products or design your products by using Sanken products the reliability largely d...