11.  Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing between the purifi er 

and point of use. This is done by introducing chlorine into the purifi er chamber, a 100-ppm of chlorine is suggested. With 
the chlorine in the purifi er chamber, turn the ultraviolet purifi er on. Open the “downstream” outlet until a chlorine odor 
is noticed. Close the outlet and allow the chlorine to remain in the plumbing for three (3) hours. Flush the plumbing with 
ultraviolet purifi ed water; allow the water to run for a minimum of 5 minutes prior to use (to insure no chlorine smell can be 
detected). This will allow the chlorine to be fl ushed from the pipes.

        CAUTION: For added protection, a suitable drain 

pan must be installed under the purifi er. The drain pan must be plumbed to an adequate, free fl owing drain to prevent 
water damage in the event of a leak. There are numerous leak detection/fl ood stop devices, available on the market 
today, designed to stop the fl ow of water, reducing the chance of water damage due to leakage. For more details 
regarding leak prevention and/or limiting damages due to leaks, please contact the factory.

R

ECOMMENDED

 O

PTIONS

1. 

Guardian™ Ultraviolet Monitor*:

 Visually indicates the level of germicidal ultraviolet energy that penetrates the quartz 

sleeve and the water within the water purifi er. The ultraviolet monitor is capable of operating an optional audio alarm and/or 
solenoid valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to:
• 

Fouling or deposits on the quartz sleeve.

• 

Poor ultraviolet transmission through the water; color, turbidity, and organic or other impurities in the water can reduce 
or interfere with the transmission of ultraviolet rays.

• 

Lamp outage or component failure. (Monitor will not function in power outage.)

• 

Depreciation of the lamp output due to usage or other cause. Lamp output gradually depreciates with use. Lamp 
replacement is recommended once each year.

2. 

Sentry™ Safety Sensor:

 Indicators provide constant visual monitoring of normal operation. In the event of ballast or lamp 

failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an optional audio alarm and/
or solenoid valve.

3. 

Steralert™:

 Lamp Status Alarm produces a high pitched, pulsed tone when the water purifi er is no longer functioning due to 

lamp or power failure.

4. 

Sure Flo™ Flow Control Valve*:

 Limits water fl ow to the rated capacity of the purifi er. The fl ow control valve is located 

in line prior to the water purifi er, and should be protected from ultraviolet exposure by the use of a 90-degree elbow fi tting 
between the fl ow control valve and the water purifi er.

5. 

Audio Alarm*:

 Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to any malfunction detected.

6. 

Solenoid Valve*:

 Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay Mechanism, this valve 

prevents water fl ow through the water purifi er when an abnormal condition is detected or in the event of power failure.

7. 

Elapsed Time Indicator:

 A non-resettable display of the water purifi er operating hours. Useful for scheduling and recording 

maintenance and lamp replacement.

8. 

Time Delay Mechanism*:

 Provides a 2-minute warm up period during which the ultraviolet lamp achieves its full 

germicidal output before the water is allowed to fl ow through the water purifi er. The time delay mechanism is used in 
conjunction with, and is electrically connected to the Solenoid Valve.

9. 

Wall Mount Kit:

 Stainless steel wall brackets provide quick and easy installation and professional fi nish. Pre-drilled and 

ready to install. Optimizes free air circulation to cool ballast housing.

10. 

Quantum Thermal Optimizer:

 Thermal relief valve used to help regulate the water temperature inside the water purifi er’s 

disinfection chamber. Since the relative ultraviolet output, of a germicidal lamp, is affected by temperature it is important to 
keep the lamp’s temperature within the peak output temperature range.

11. 

Safety Goggles: 

Safety eyewear should be used as general-purpose safety protection and for additional shielding from 

Ultraviolet rays

12. 

Gloves: 

Gloves should be worn to offer hand protection from sharp threats like glass, wire, and metal. 

* Use of this option is recommended by U.S. Public Health Service “Criteria for Acceptability of an Ultraviolet Disinfection 
Unit.” Originally issued April, 1966.

NOTE: The recommended options above are available from Atlantic Ultraviolet Corporation or a distributor of Atlantic 
Ultraviolet Corporation’s products. For the other devices that may be required for your application, please contact your 
local water treatment dealer, plumber or plumbing supplier.

 

    

Summary of Contents for S17A

Page 1: ...DXSSDXJH 1 D H PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1377B9 August 2014 2014 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Installation ULTRAVIOLET WATER PURIFIERS ...

Page 2: ...ctions generally describe the installation operation and maintenance of the SANITRON line of water purifiers Models S17A S23A S37C and S50C Questions that are not specifically answerable by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damages Do not in...

Page 3: ... operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the water purifier 15 SAVE THESE INSTRUCTIONS This symbol pictorial is used to identify the need to wear protective gloves Caution indicates a POTENTIALLY hazardous situation which if not avoide...

Page 4: ...is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port or optional ultraviolet monitor provides visual indication of germici...

Page 5: ...d in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There ar...

Page 6: ...upply which is required when removing the quartz sleeve 7 Unions should be installed on both the inlet and outlet of the water purifier this will allow easy removal of the water purifier from the plumbing if required Apply Teflon tape to threads of inlet and outlet ports to ensure a tight seal 8 When all plumbing connections are complete allow water to enter the water purifier at a low flow rate u...

Page 7: ...tatus Alarm produces a high pitched pulsed tone when the water purifier is no longer functioning due to lamp or power failure 4 Sure Flo Flow Control Valve Limits water flow to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control val...

Page 8: ...on or manganese Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the water that passes through the ultraviolet purifier If you encounter difficulty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency of cleaning may be extend...

Page 9: ... wire away from the socket 3 Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on opposite end of chamber 4 While holding lamp end carefully remove lamp socket on end now exposed 5 Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be...

Page 10: ... is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push wiper back in toward the purifier until it reaches its second stop 4 Repeat steps 2 and 3 as necessary 5 Holding wiper in place return wiper clip and snap over wiper rod in front of the wiper lock s...

Page 11: ... washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a d...

Page 12: ...16 wrench to loosen and remove the 1 4 nut from the head clamp 4 Withdraw chamber head and wiper assembly from the chamber 5 Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 6 Carefully discard all pieces of the broken quartz sleeve 7 Inspe...

Page 13: ...nspected and can be replaced if worn or damaged 8 Reassemble replacing the o rings quartz rod and securing in place with the quartz rod sensor probe cap Tighten the quartz rod sensor probe cap by hand only DO NOT USE HAND TOOLS Tightening with hand tools may damage the quartz rod or o ring seal 9 Reinstall sensor probe into the center fitting of the chamber and hand tighten 10 Slowly restore water...

Page 14: ...e connections or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR Low UV intensity As indicated on optional GuardianTM Ultraviolet Monitor Quartz sleeve fouled Clean quartz sleeve see Quartz Sleeve Cleaning in the Maintenance Section Sensor Probe if eq...

Page 15: ...in Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight Port Translucent Sight Port Ultraviolet Monitor Optional Optional Optional Optional Flow Control Valve Optional Optional Optional Optional Audio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional ...

Page 16: ...16 REPLACEMENT PARTS SANITRON MODELS S17A S23A Figure 9 Exploded View S17A S23A ...

Page 17: ...1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw No 8 x 3 8 long 4 50 1323 4 50 1323 22 Speed Nut 6 32 2 50 1314 2 50 1314 23A Ballast 120v 60Hz 1 10 0137 1 10 0137 23B Ballast 220v 50Hz 1 10 0136 1 10 0136 24 Screw Mo...

Page 18: ...18 SANITRON MODELS S37C S50C Figure 10 Exploded View S37C S50C ...

Page 19: ...25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 22 Lock Washer 1 4 4 50 1321 4 50 1321 23 Flat Washer 1 4 4 50 1317 4 50 1317 24 Ballast Housing Cover 1 25 0394A 1 25 0350A 25 Screw No 8 x 3 8 long 8 50 1323 8 50 1323 26 Speed Nut 6 32 2 50 1314 2 50 1314 27A Ballast...

Page 20: ... has been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be construed as promoting or sanctioning unauthorized use Atlantic Ultraviolet Corporation makes every effort to ensure that the SANITRON Ultraviolet Water Purifiers are products of superior quality a...

Reviews: