Sanitron S17A Owner'S Manual Download Page 5

5

INSTALLATION

L

OCATION

1.  The water purifi er is intended for indoor use only. The water purifi er is designed to mount horizontally. The water purifi er 

should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area 
surrounding the water purifi er, should be between 35

o

 F and 100

o

 F.

2.  Electrical power supplied to the water purifi er 

MUST

 match power requirements listed on the water purifi er. Use of a voltage 

surge protector is recommended.

3.         Plug water purifi er only into an approved ground fault circuit interrupt (GFCI) receptacle.

4.  The water purifi er should be located in a dry, well-lit area, which provides enough room to perform routine maintenance. This 

includes a minimum distance of one chamber length from the wiper end, to allow for cleaning and/or the changing of the 
lamp and quartz sleeve as well as a minimum of 6” on the opposite end of the water purifi er. Minimum clearance to fl oor 18’’.

5.  The water purifi er should always be located closest to the point of use. This reduces the chance of the purifi ed water being 

re-contaminated by bacteria in the water distribution system after the water purifi er.

6. 

CAUTION:

 As with any water handling device, the water purifi er should be located in an area where any possible 

condensation or leakage from the water purifi er, any purifi er accessory and/or plumbing will not result in damage  to the 
area surrounding the water purifi er. For added protection, it is recommended that a suitable drain pan be installed under the 
purifi er. The drain pan must be plumbed to an adequate, free fl owing drain to prevent water damage in event of a leak. There 
are numerous leak detection/fl ood stop devices, available on the market today, designed to stop fl ow of water, reducing the 
chance of water damage due to leakage. For more details regarding leak prevention and/or limiting damages due to leaks 
please contact factory.

7.  The water purifi er should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon Filters, Pre-

Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purifi ed water being re-contaminated by 
bacteria in any of these units.

D

IMENSIONAL

 D

ATA

Figure 1 - SANITRON

®

 Dimensional Drawing

Table 2 - SANITRON

®

 Dimensional Data

Model

A

B

C

D

E

F

G

H

J

Inlet/Outlet

S17A

8-3/4”

17”

8-3/4”

10”

17-3/8”

3-5/8”

4-5/16”

8-3/16”

7-3/16”

3/4”m NPT

S23A

14-3/4”

23”

13-1/4”

14-1/2”

23-3/8”

3-5/8”

4-5/16”

8-3/16”

10-3/16”

3/4”m NPT

S37C

28-1/2”

37”

16”

18”

37-3/8”

4-15/16”

5-11/16”

9-1/2”

11-1/8”

1”m NPT

S50C

40-7/8”

50”

26”

30”

50-3/8”

4-15/16”

5-11/16”

9-1/2”

13-13/16”

1- 1/2”m  NPT

All specifi cations, dimensional data, etc are approximate and subject to change without notice.

Summary of Contents for S17A

Page 1: ...DXSSDXJH 1 D H PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1377B9 August 2014 2014 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Installation ULTRAVIOLET WATER PURIFIERS ...

Page 2: ...ctions generally describe the installation operation and maintenance of the SANITRON line of water purifiers Models S17A S23A S37C and S50C Questions that are not specifically answerable by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damages Do not in...

Page 3: ... operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the water purifier 15 SAVE THESE INSTRUCTIONS This symbol pictorial is used to identify the need to wear protective gloves Caution indicates a POTENTIALLY hazardous situation which if not avoide...

Page 4: ...is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port or optional ultraviolet monitor provides visual indication of germici...

Page 5: ...d in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There ar...

Page 6: ...upply which is required when removing the quartz sleeve 7 Unions should be installed on both the inlet and outlet of the water purifier this will allow easy removal of the water purifier from the plumbing if required Apply Teflon tape to threads of inlet and outlet ports to ensure a tight seal 8 When all plumbing connections are complete allow water to enter the water purifier at a low flow rate u...

Page 7: ...tatus Alarm produces a high pitched pulsed tone when the water purifier is no longer functioning due to lamp or power failure 4 Sure Flo Flow Control Valve Limits water flow to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control val...

Page 8: ...on or manganese Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the water that passes through the ultraviolet purifier If you encounter difficulty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency of cleaning may be extend...

Page 9: ... wire away from the socket 3 Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on opposite end of chamber 4 While holding lamp end carefully remove lamp socket on end now exposed 5 Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be...

Page 10: ... is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push wiper back in toward the purifier until it reaches its second stop 4 Repeat steps 2 and 3 as necessary 5 Holding wiper in place return wiper clip and snap over wiper rod in front of the wiper lock s...

Page 11: ... washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a d...

Page 12: ...16 wrench to loosen and remove the 1 4 nut from the head clamp 4 Withdraw chamber head and wiper assembly from the chamber 5 Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 6 Carefully discard all pieces of the broken quartz sleeve 7 Inspe...

Page 13: ...nspected and can be replaced if worn or damaged 8 Reassemble replacing the o rings quartz rod and securing in place with the quartz rod sensor probe cap Tighten the quartz rod sensor probe cap by hand only DO NOT USE HAND TOOLS Tightening with hand tools may damage the quartz rod or o ring seal 9 Reinstall sensor probe into the center fitting of the chamber and hand tighten 10 Slowly restore water...

Page 14: ...e connections or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR Low UV intensity As indicated on optional GuardianTM Ultraviolet Monitor Quartz sleeve fouled Clean quartz sleeve see Quartz Sleeve Cleaning in the Maintenance Section Sensor Probe if eq...

Page 15: ...in Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight Port Translucent Sight Port Ultraviolet Monitor Optional Optional Optional Optional Flow Control Valve Optional Optional Optional Optional Audio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional ...

Page 16: ...16 REPLACEMENT PARTS SANITRON MODELS S17A S23A Figure 9 Exploded View S17A S23A ...

Page 17: ...1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw No 8 x 3 8 long 4 50 1323 4 50 1323 22 Speed Nut 6 32 2 50 1314 2 50 1314 23A Ballast 120v 60Hz 1 10 0137 1 10 0137 23B Ballast 220v 50Hz 1 10 0136 1 10 0136 24 Screw Mo...

Page 18: ...18 SANITRON MODELS S37C S50C Figure 10 Exploded View S37C S50C ...

Page 19: ...25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 22 Lock Washer 1 4 4 50 1321 4 50 1321 23 Flat Washer 1 4 4 50 1317 4 50 1317 24 Ballast Housing Cover 1 25 0394A 1 25 0350A 25 Screw No 8 x 3 8 long 8 50 1323 8 50 1323 26 Speed Nut 6 32 2 50 1314 2 50 1314 27A Ballast...

Page 20: ... has been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be construed as promoting or sanctioning unauthorized use Atlantic Ultraviolet Corporation makes every effort to ensure that the SANITRON Ultraviolet Water Purifiers are products of superior quality a...

Reviews: