20
EN
ENGLISH
Actuate
Main flush
Stop flushing for
3 minutes
Send stored data to
other units
Data collection
Start button and ack-
nowledge button
Setting
Setting by bidirectional remote maintenance and service controller DO-5.1 S
Parameter
Factory setting
Setting ranges
Function
Range
15
(≈ 50 cm)
1 - 20
(≈ 20 - 70 cm)
Range of infrared sensor
Pre-flushing
ON
ON
OFF
When a user is detected an automatic pre-flushing of
0.8 seconds takes place to wet the ceramic and avoid
deposits. This function has an interval of 5 minutes.
Should a second user be detected within five minutes,
there will be no pre-flushing.
Main flush time
4 seconds
3-4-5-6-8
seconds
Flush time after use
Final flush
OFF
OFF
6-8-10-12-14-16-
18-20-22-24
seconds
To ensure a complete refill of the odour trap, a 0.5 se
-
conds flush follows the main flush within the time set.
Cleaning flush
OFF
OFF
1-3-6-12-24-48-72-
96-108 hours
Does a cleaning flush of 10 seconds at the interval
set. The interval starts with initial use.
Hygiene
period K
24 hours
OFF
1-3-6-12-24-48-72-
96-108 hours
Initiates an automatic flush at the time interval set.
The interval always starts from the last use.
Hygiene
flush time
4 seconds
3-4-5-10-15-30-60
90-120-150-180
seconds
Flush time of interval flush
Stagnation time
10 minutes
0-5-10-30
seconds
1-3-5-10-30
minutes
1-3-6-12 hours
Preset stagnation time is permitted, i.e. all flushes
with a total distance smaller than this time are added
and analyzed whether they comply with the preset
hygiene flush time.
Stop time
3 minutes
1 - 10 minutes
Stops flushing for the set period
(cleaning and maintenance activities)
Long stop time
6 hours
0,5 - 12 hours
Stops flushing for the set period
(exposure time of cleaners)
After that time an automatic flush takes place to rinse
the ceramic.