background image

GENERAL FEATURES 

This mixer is suitable for all water heating systems provided it is installed correctly by a 

competent and qualified installer. 

OPERATING SPECIFICATIONS 

Hot water supply temperature: 

Maximum

:

 

 85°C 

Advisable:

 

65°C

Minimum: 

 

5°C 

Minimum difference between hot and mixed temperature 10°C 
The temperature of the inlet hot water must be higher than the maximum mixed water 

temperature required from the outlet. 

Working pressures

Maximum: 10 bar 

Minimum:

 

1 bar

 

Hot  and  cold  operating  pressures  should  be  kept  as  balanced  as  possible  in  order  to 

maintain maximum efficiency. 

When the supply pressure is higher than 5 bar a pressure reducing valve should be fitted 

before the shower mixer. 

TECHNICAL DATA 

The mixer is supplied with a cover plate for the installation at a depth from 70 mm to 89 mm. 

The temperature control knob is pre-set from the manufacturer at 38°C. 

The mixer ports are supplied with a female thread G ½”, G ¾”, NPT½”, NPT ¾”. 

The thermostatic mixer is provided with an additional outlet at the base of the  mixer. When 

using the bottom outlet a flow control is required between the mixer and the outlet. 

The bottom outlet is sealed with a removable plug. 

PLUMBING RECOMMENDATIONS 

An independent hot and cold water supply is required for the shower system.

The recommended pipe work should be 22mm minimum for low pressure system.

If  more  than  one  shower  mixer  is  installed,  the  minimum  feed  should  be  28mm.

(ensure adequate supply of both hot and cold water can be maintained)

READ  CAREFULLY  THIS  MANUAL  BEFORE  USING  YOUR  MIXER  AND  KEEP  IT  AT

HAND FOR FUTURE REQUIREMENTS

Summary of Contents for Bagno Design Revolution

Page 1: ...REVOLUTION Concealed part for thermostatic shower mixer with 2 Outlets ...

Page 2: ... mixer TECHNICAL DATA The mixer is supplied with a cover plate for the installation at a depth from 70 mm to 89 mm The temperature control knob is pre set from the manufacturer at 38 C The mixer ports are supplied with a female thread G G NPT NPT The thermostatic mixer is provided with an additional outlet at the base of the mixer When using the bottom outlet a flow control is required between the...

Page 3: ...INSTALLATION Consider the thickness of the final coating tiles marble etc Keep a 135x100 mm hole in the wall to cut the protection and for the future maintenance of the product ...

Page 4: ...The plate slides from a minimum of 21 mm to a maximum of 1mm ...

Page 5: ...s the correct fittings for the type of tube chosen for your hydraulic system ATTENTION Fittings not supplied Use a level to find the correct position For the in wall installation drill the wall and use the plugs and screws to fix the box to thewall ...

Page 6: ...For the frame installation use the screws to fix the box to the woods For the rear installation use the screw to fix the box to the drywall ...

Page 7: ... made of plastic material ATTENTION Never expose box to open flame or excessive heat In case of mixer ports NPT threaded use fittings with a minimum length of 3 Before tiling attach the seal to the wall with glue ...

Page 8: ...TRIM FIXING Once the mixer is installed in the wall cut along the finished wall and remove the plastic guard Put the silicone between the plastic guard and the finished wall ...

Page 9: ...late is against the wall Fix the brass insert 6 and fix the screw 7 Position the closure handle 8 on the insert 6 and rotate until the vertical position is reached REFER TO IMAGE BELOW Fix the grub screws 9 with a 2 5 Allen key Fix the small cap 10 Fix the thermostatic handle 11 Fix the grub screw 12 and the small cap 13 ...

Page 10: ...eave to soak in vinegar in presence of limestone Grease the O rings and if damaged replace them with new ones 2x OR 2100 mm 25 12 x 1 78 1x OR 2106 mm 26 7 x 1 78 5 Assemble the trim following the instructions of TRIM FIXING VALVE HOLDER 1 Close the water inlets 2 Unscrew the valve holders 3 anti clockwise with a 27mm wrench DO NOT USE A SCREW DRIVER 3 Remove the valve holders and clean the filter...

Page 11: ...TWO WAY DIVERTER ...

Page 12: ... water inlets 2 Unscrew the threaded rod 1 3 Unscrew the headwork 2 anti clockwise with a 17 wrench 4 5 Remove the diverting cartridge 3 Before replacing the cartridge clean thoroughly and grease the inner seat of the body 7 Screw the flange 2 and the threaded rod 1 6 Replace the cartridge 3 Place the pivot in its seats 8 Assemble the trim following the instructions shown in section TRIM FIXING ...

Page 13: ... corrosive chemicals should be used In case of prolonged disuse of the mixer in winter time it is recommended to close the system and empty the mixer to avoid damages caused by frost NOTES If these simple instructions are followed this mixer will give many years of satisfactory use The company has policy of continuous improvement and reserve the right to change specification without notice ...

Page 14: ... cold water flowing through the mixer The cold water inlet is restricted a b Temperature has decreased below the minimum required Inverted connections Inverted mixer a b a Inverted connections Inverted mixer a b a Control the check valves b Check if the inlet filters are cleaned c d Check if the connecting pipes are cleaned e Control if the check valves are fully open Reduce the water flow of all ...

Page 15: ...Note ...

Page 16: ...INM MIX T302 CON 02 20 ...