If the room temperature cannot reach the setpoint temperature set up in less than
60 minutes, then the thermostat will trigger the heat automatically. The heat «icon»
will then be blinking.
By pr on the setpoint temperature adjustment screen, SET will be blinking
and the setpoint temperature will automatically be set at 35° C for this set up
programm anticipation heat phase.
Function principle
The thermostat will save the room ambiant temperature during heating periods (
temperature increasing phases) over a rolling 7 day period. It will thus calculate the
necessary time needed to reach the comfort temperature of a heating period and
will anticipate heating order triggering accordingly.
When the thermostat is in anticipation phase, the screan displays a blinking «SET»,
the setpoint temperature is switched automatically to 35°C and will afterwards
automatically go back to the temperature set at the beginning of the progrmmed
period.
The maximum anticipation is limited to 60 minutes.
Function activation or disactivation
Press
until screen shuts down, release et press again until screen lights up
again.
Reach menu 9 by pressing 8 x
.
Press + or - select 0 = OFF or 1 = ON.
Press
to exit the function
23