12. Norms

The unit conforms with EN 12050-2 waste water lifting plant.

SANISPEED®

Société Française d’Assainissement

EN 12050-2

FF02-V45
220 - 240 V - 50 Hz - 400 W - IP44  2A - 6,4 KG

13. Care and use

The Sanispeed is designed to handle the waste evacuation from a bath, kitchen sink, dishwasher and washing machine - in a light commercial 
situation. Its powerful pump will deal with every day normal usage.

Warning

: Do not dispose of solvents, paints (do not wash paint brushes in sink), caustic, acid or other chemicals into these products.

Depending on usage, the unit may need to be cleaned from time to time. Heavy usage can result in a build up of fat and grease.

The unit will pump away water as hot as 90°C for 5 minutes (i.e. to clear the hottest waste water from a washing machine). However, do not pour 
boiling water directly into the unit.

When pumping very hot water for a prolonged period of time, the unit will automatically cut out to protect the motor (thermal cut-out). When 
this happens the unit will shut down long enough to cool down (approx.1 hour) and automatically resume normal operation when ready.

14. Dismantling

Disconnect from the power supply before attempting any work on the unit.
The unit does not require any specific maintenance.
In case of a service requirement, please call the Saniflo service engineer, especially for any electrical work.

15. Guarantee

2 years guarantee as from its date of purchase subject to correct installation and correct use.

11. Electrical connection

 

The electrical installation should be carried out by a qualified person.

All wiring must conform to BS7671, 1992 requirements for electrical installations. The Sanispeed requires a 
220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanispeed to a conventional plug 
and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The 
Sanispeed has an earth wire. The wires in the mains lead are coloured in accordance with the following code:

Brown – Live       Blue – Neutral       Green/Yellow – Earth

Warning:

 Ensure the electricity is turned OFF at the main switchboard before wiring to connector.

All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, 
as special tools are required.

UK – 230/240V 50Hz.

The unit should be installed so it is easily accessible/removable for possible maintenance.  
The unit should not be exposed to splashing in normal use.

CANADA
USA

EUR

CH

GB

Summary of Contents for SANISPEED

Page 1: ... follow instructions could result in poor functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included A B C E F G I x2 Discharge elbow D Air vent cover Metal...

Page 2: ...6 mm 185 mm 92 5 mm 139 4 mm Vertical Height metres Flow Rate L min max 70m 2m 3m 4m 5m This unit is for domestic use only 4 Performance Curve Height and Length of the discharge pipe 6m Max 7m max 20m max 10m 1 2 3 4 5 6 7 8 3 7 20 30 40 50 60 70 80 90 100 110 120 ø 32 The discharge pipe size for Sanispeed must be 32mm ...

Page 3: ... of the piperun I H 6 Connection to side inlets Use the rubber connector A for connection of pipes to the side inlets Secure with the metal hose clips G Cap off unused inlets with the end caps C provided after greasing the joints I H C G A G C G A G 7 Connection to lid inlets To connect to a lid inlet cut off the sealed cap with a hacksaw and connect using the rubber connector A provided Tighter w...

Page 4: ...of 1 100 10mm per metre all the way to the drain Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem Orient the ope...

Page 5: ...m the power supply before attempting any work on the unit The unit does not require any specific maintenance In case of a service requirement please call the Saniflo service engineer especially for any electrical work 15 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use 11 Electrical connection The electrical installation should be carried out...

Page 6: ...16 Parts ...