background image

1. Description

This unit is a pump that will clear the waste from a shower and washbasin, bath, washing machine, glass washer and a sink in a light commercial 
situation.

The unit will start automatically.

Please pay particular attention to the following:

Possible danger to personnel  

Warning of possible electrical hazard

“ATTENTION”  This is a general warning that failure to follow instructions could result in poor functioning of the unit.

This equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by 
this new generation of appliances, it is important to comply with the installation instructions in section 5.

2. List of Accessories included

A

B

C

E

F

G

I

x2

Discharge elbow

D

Air vent cover

Metal hose clip

Metal hose clip

Metal hose clip

H

Floor mounting screws

Floor mounting bracket

End cap

Rubber connector

x2

x6

x1

40 x 60mm

x1

x1

x2

x1

x3

32 x 50mm

25 x 40mm

Summary of Contents for SANISPEED

Page 1: ... follow instructions could result in poor functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included A B C E F G I x2 Discharge elbow D Air vent cover Metal...

Page 2: ...6 mm 185 mm 92 5 mm 139 4 mm Vertical Height metres Flow Rate L min max 70m 2m 3m 4m 5m This unit is for domestic use only 4 Performance Curve Height and Length of the discharge pipe 6m Max 7m max 20m max 10m 1 2 3 4 5 6 7 8 3 7 20 30 40 50 60 70 80 90 100 110 120 ø 32 The discharge pipe size for Sanispeed must be 32mm ...

Page 3: ... of the piperun I H 6 Connection to side inlets Use the rubber connector A for connection of pipes to the side inlets Secure with the metal hose clips G Cap off unused inlets with the end caps C provided after greasing the joints I H C G A G C G A G 7 Connection to lid inlets To connect to a lid inlet cut off the sealed cap with a hacksaw and connect using the rubber connector A provided Tighter w...

Page 4: ...of 1 100 10mm per metre all the way to the drain Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem Orient the ope...

Page 5: ...m the power supply before attempting any work on the unit The unit does not require any specific maintenance In case of a service requirement please call the Saniflo service engineer especially for any electrical work 15 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use 11 Electrical connection The electrical installation should be carried out...

Page 6: ...16 Parts ...