10. Norms
This appliance conforms to EN 12050-3.
Lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical
safety and electromagnetic compatibility.
SANIPLUS®
Société Française d’Assainissement
EN 12050-3
LA01-x10
220 - 240 V - 50 Hz - 550 W - IP44 2,9A - - 5,4 KG
11. Commissioning the unit
Once electrical and plumbing connections have been made, flush the WC once. The motor should run from 5 to 10 seconds (sometimes in several
small bursts) to clear the waste (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is clear,
and that the discharge hose is not kinked. Flush the WC checking that all seals, and connections are watertight. Check the discharge pipework
from the unit.
9. Electrical connection
The electrical installation should be carried out by a qualified person.
All wiring must conform to BS7671, 1992 requirements for electrical installations. The Saniflo requires a 220/240V
single phase AC 50 Hz supply (UK specification). Do not connect the Saniflo to a conventional plug and socket. It
must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Saniflo has an earth
wire. The wires in the mains lead are coloured in accordance with the following code:
Brown – Live Blue – Neutral Green/Yellow – Earth
Warning:
Ensure the electricity is turned OFF at the main switchboard before wiring to connector.
All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent,
as special tools are required.
UK – 230/240V 50Hz.
The unit should be installed so it is easily accessible/removable for possible maintenance.
The unit should not be exposed to splashing in normal use.
CANADA
USA
EUR