Sanhua SD2 series drive
5
User Manual v3.5 –Sep-27.2022
Recommended liquid tube layout
:
The output mechanical frequency range depends on specific compressors.
2.2.1 Power supply of drive
The drive can be used in the following power supply environments:
1-PH
3-PH
Remark
Fully Load Operation Voltage
AC200V~240V
AC360V~440V
N
ominal
Working Voltage range
AC176V~264V
AC320V~480V
Not marked on Nameplate
Allowable input range
≤AC 300V
AC240V~520V
No damage at 1sec transient
Power Supply Frequency: 50/60Hz ±5%
Tab.2.3
2.2.2 Accessories
Drive Type
Label Name
Accessories
1-PH Drive
SD2011A2
/
SD2015A2
/
SD2020A2
/
3-PH Drive
SD2015B4
Choke: 3*LE76-0825
SD2020B4
Choke: 3*LE105-1325
SD2025B4
Choke: 3*LE85.8-2503B
SD2032B4
Choke: 1*R3515
Tab.2.4
Summary of Contents for SD2 Series