CHANGE THE TEMPERATURE FOR A SET NUMBER OF HOURS

You can also set the thermostat to hold at the temperature you want for a defined 
number of hours.

1.  Press M to enter override mode then select temperature using 

▼▲

 and press Ok.

2.  Select number of hours using 

▼▲

 and press Ok.

3.  Comfort Override, Temp. Set & Hours, with the hours remaining, are shown on the 

display.

To cancel setting and return to normal operation press 

Ok.

CHANGE THE TEMPERATURE

To manually change the temperature temporarily you simply press the raise or lower 
buttons to the desired level, if left alone this will stay set until the next programmed 
change at which point it returns back to the original schedule.

1.  Choose desired temperature using 

▼▲

To cancel setting early and return to normal operation press 

Ok.

Temporary Override

is shown above the

time on the display

Comfort Override

is shown above the

time on the display.

Time changes to 

countdown of the 

remaining hours and

minutes.

Summary of Contents for Choice RSTAT5 RF

Page 1: ...your home is already at your desired temperature When you set a temperature you are saying you don t want the heating to come on unless the room temperature is lower than the set temperature WHAT IS A...

Page 2: ...C Boiler ON Boiler ON Boiler ON Boiler OFF Boiler OFF Boiler OFF SETTING THE TIME AND DATE Before you set the thermostat you should fix the time and date 1 Press and hold Set for 6 seconds 2 Choose be...

Page 3: ...t person leave in the morning Noon If anyone is home at lunchtime when Break and when do they leave again EVEN What time does the first person get back home in the afternoon evening NIGHT What time is...

Page 4: ...the temperature it will set to at that point As can be seen the NIGHT setting carries over stays until the MORN time the following day If you don t need a certain program to be there for example you...

Page 5: ...thermostat will return to normal operation if no buttons are pressed for 30 seconds To exit programming mode either wait 30 seconds or press Set x2 and Ok NB Each day s end time is 11 59 in 12hr or 2...

Page 6: ...nd return to normal operation press Ok CHANGE THE TEMPERATURE To manually change the temperature temporarily you simply press the raise or lower buttons to the desired level if left alone this will st...

Page 7: ...ure at a desired set point until a specific date 1 Press M x3 to enter holiday mode then select temperature using and press Ok 2 Select the Month and Year using and press Ok 3 Select the Day using and...

Page 8: ...prior notice Sangamo Limited Industrial Estate Port Glasgow Renfrewshire PA14 5XG Tel 01475 745131 Fax 01475 600370 Email enquiries sangamo co uk Web www sangamo co uk WEE JH0069TY CHANGING THE BATTE...

Reviews: