background image

SBOX-7210 - User Guide, Rev. 1.0 

 
www.kontron.com 

 

// 53 

 

Figure 17: BIOS Main Menu Screen System Data and Time 

BIOS SETUP UTILITY 

Main 

Advanced 

Security 

Power 

Event Logs 

Boot 

Save & Exit 

BIOS Information 

 

 

 

 

 

BIOS Vendor 

American Megatrends 

 

BIOS Build Date 

Fujitsu 

 

Compliancy 

UEFI 2.7; PI 1.6 

 

 

 

 

> System Information 

 

 

> Open Source Software License Information   

 

: Select Screen 

 

 

 

: Select Item 

System Date 

[Tue 09/08/2020] 

Enter: Select 

System Time 

[01:51:34] 

+/-: Change Opt. 

System Language 

[English] 

F1: General Help 

 

 

F2: Previous Values 

Access Level 

Administrator 

F3: Optimized Defaults 

 

 

F4: Save & Exit 

Keyboard Layout 

[English] 

ESC: Exit 

Version 2.20.1271. Copyright (C) 2019, American Megatrends, Inc. 

 

Feature 

Option 

Description 

System Date 

[dd/mm/yyyy] 

Set the Date. Use Tab to switch between Data elements. 

System Time 

[hh:mm:ss] 

Set the Time. Use Tab to switch between Time elements. 

System Language 

[English], [Japanese] 

Choose the system default language 

Keyboard Layout 

[English], [Spanish], 
[French], [Brazilian], 
[Dutch], [German], 
[Italian], [Swedish], 
[Danish], [Finnish], 
[Norwegian], 
[Russian], [Japanese], 
[Korean], [Chinese] 

Select the keyboard layout for your attached keyboard 

 

 

Summary of Contents for Kontron SBOX-7210

Page 1: ...USER GUIDE www kontron com SBOX 7210 Doc User Guide Rev 1 0 Doc ID To be Determined...

Page 2: ...SBOX 7210 User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank...

Page 3: ...be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions whic...

Page 4: ...y at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all legal...

Page 5: ...t Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths into a s...

Page 6: ...cribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Page 7: ...before performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be disconn...

Page 8: ...oduct then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental M...

Page 9: ...ity 17 2 1 Electromagnetic Compatibility EU 17 2 2 FCC Statement USA 17 2 3 EMC Compliance Canada 17 3 Shipment and Unpacking 18 3 1 Unpacking 18 3 2 Scope of Delivery 18 3 2 1 Standard 18 3 2 2 Optio...

Page 10: ...able Processors 32 6 2 Convection Cooling 32 6 3 System Clearance 32 6 4 Maximum Temperatures 32 6 5 Third Party Components 32 7 Installation Instructions 34 7 1 System Mounting 35 7 1 1 Desktop Insta...

Page 11: ...s 10 50 Table 16 PS 2 Mouse Connector see Figure 2 pos 11 50 Table 17 Hotkeys Table 51 Table 18 Main Setup Menu Sub Screens and Functions 52 Table 19 List of Acronyms 98 List of Figures Figure 1 Front...

Page 12: ...Figure 36 BIOS Advanced Menu Super IO Configuration Serial Port 2 Configuration Serial Port Mode Selection73 Figure 37 BIOS Advanced Menu Serial Port Console Configuration 74 Figure 38 BIOS Advanced M...

Page 13: ...sufficient air circulation is available to cool the product please ensure that the ventilation openings are not covered or blocked If an air filter is provided this should be cleaned regularly Do not...

Page 14: ...ndirectly a reliable protective earthing connection is provided a suitable easily accessible disconnecting device is used in the application e g overcurrent protective device if the device itself is n...

Page 15: ...non conductive materials such as ordinary plastic assembly aids and Styrofoam 7 Use only field service tools which are conductive such as cutters screwdrivers and vacuum cleaners 8 Always place drive...

Page 16: ...on com 16 Do not dispose of lithium batteries in general trash collection Dispose of the battery according to the local regulations dealing with the disposal of these special materials e g to the coll...

Page 17: ...ed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If th...

Page 18: ...nconsistencies between the contents and your order please contact Kontron for help and information 3 2 Scope of Delivery 3 2 1 Standard 1x SBOX 7210 corresponding to the ordered system configuration 1...

Page 19: ...served for DP 3x Aperture reserved for USB Type A port 1x Aperture reserved for RS232 422 485 DB9 COM port Standard Baseboard and System Expansion Capabilities 2x DDR4 SO DIMM memory socket 1x SATA da...

Page 20: ...xpand the system with a 2 5 SATA HDD SSD drive 4 1 2 System Expansion via mPCIe Interface The baseboard comes with an onboard mPCIe interface connector The connector is intended to be used to install...

Page 21: ...ite The system must be attached by means of the power cord to an appropriate mains DC Even when the system is turned off via the power button there is still a standby voltage on the baseboard The unit...

Page 22: ...PCIe x4 Add on Card Slot see Chapter 4 3 12 13 Aperture for WLAN Antenna Port see Chapter 4 3 13 14 Kensington Security Slot see Chapetr 4 3 14 15 Aperture reserved for DP Port see Chapter 4 3 15 16 A...

Page 23: ...nal to amplified speakers or headphones 4 3 6 GbE LAN These connectors are Gigabit Ethernet 10 100 1000 Mbit s IEEE 1588 capable interfaces The connectors are standard 8 pin RJ45 type connectors with...

Page 24: ...lot The slot is used for attaching a lock and cable apparatus Locks are generally secured in place with a key or combination lock attached to a rubberized metal cable Users can use it to attach SBOX 7...

Page 25: ...4 4 3 5 M 2 Key M Socket see Chapter 4 4 4 6 PCIe x16 Socket see Chapter 4 4 5 7 Half sized mPCIe fixing bolt 8 Full sized mPCIe fixing bolt 9 M 2 fixing bolt for Key M type 2242 10 M 2 fixing bolt fo...

Page 26: ...ket The SBOX 7210 reserves one mPCIe socket Figure 4 pos 4 allowing itself being extended with a half sized or full sized mPCIe WLAN or WLAN Bluetooth combo card 4 4 4 M 2 Key M Socket The SBOX 7210 r...

Page 27: ...in this manual Only personnel with appropriate qualifications trainings and authorization are permitted to install and work with the device The installation removal of HHD SSD and or expansion cards m...

Page 28: ...to work on For opening and closing the SBOX 7210 please perform the following steps 1 Close all applications Shut down the system properly and disconnect the connection to the main power source Disco...

Page 29: ...of removing or installing a 2 5 SATA HDD SSD or mPCIe expansion card When used as intended the SBOX 7210 is to operate only in closed condition Only when the access cover is properly fixed with the sc...

Page 30: ...k bracket to the system by placing the hooks of the bracket Figure 4 pos 14 on the designed holes in the chassis and pushing it forward 6 Secure the hard disk bracket on the chassis with the retained...

Page 31: ...ing socket and rotate it down with the fixing hole of the M 2 SSD over the fixing bolt 4 Press the M 2 SSD down on the side with the fixing hole and secure it with the available fastening screw 5 In o...

Page 32: ...provide a maximum of airflow through and around the box proper distances to surrounding parts must be observed 6 4 Maximum Temperatures The maximum system ambient temperature depends mostly on the po...

Page 33: ...d configured with third party components like mPCIe M 2 expansion card s and hard drives HDD or SSD it has to be taken into account that the air temperature inside the system is higher than the ambien...

Page 34: ...reign objects inside the chassis The SBOX 7210 has to be installed and operated only by trained and qualified personnel Only personnel with appropriate qualifications trainings and authorization are p...

Page 35: ...with plastic clips Figure 8 pos 3 attached on each and four screws Figure 8 pos 2 Figure 8 Desktop stand kit 1 Desk Stand Bracket 2 Screw 3 Tenon to fix desk stand bracket to the chassis 4 Push button...

Page 36: ...e the brackets forward until the screw holes Figure 8 pos 5 of the brackets and the screw holes of the chassis are exactly on the same position 4 Secure the desk stand brackets to the chassis by the s...

Page 37: ...ount kit 1 Wall Mount Bracket 2 Screw Figure 14 Hole pattern of wall mount kit for SBOX 7210 unit mm To install the SBOX 7210 please proceed according to the steps described 1 Prepare the mounting sur...

Page 38: ...y the supplied screws Figure 13 pos 2 5 Place the SBOX 7210 on the mounting surface and then secure it to the mounting surface by screwing the wall mount kit to the mounting surface 6 Now the SBOX 721...

Page 39: ...2 DC Power Connection The SBOX 7210 is connected by a DC power input jack Figure 2 pos 1 to a DC power source The SBOX 7210 is delivered with a power adapter to convert AC voltage into DC 12 V and a...

Page 40: ...nnections attached to the system should be the power wires The SBOX 7210 must be connected DC main power supply complying with the SELV Safety Extra Low Voltage requirements of EN 60950 1 standard It...

Page 41: ...ts Your system is fully operational when you switch it on for the first time If you have ordered the SBOX 7210 without a pre installed operating system you will need to install the operating system an...

Page 42: ...for proper operation For light soiling clean the SBOX 7210 with a dry cloth Carefully remove dust from the surface of the chassis using a clean soft brush Stubborn dirt should be removed using a mild...

Page 43: ...J45 on rear 1x Intel I219 LM 1x Intel I210 AT Peripheral Connection USB 2x USB 3 1 Type A on rear 3x USB 2 0 Type A on rear Serial Port 1x RS232 DB9 on rear Other I Os 1x PS 2 Keyboard Mini DIN on rea...

Page 44: ...upport Windows 10 Linux 64 bit 10 1 Mechanical Specifications Table 3 Mechanical Specifications Construction Metal Chassis with Plastic Front I O Panel Dimensions W x D x H 250 mm x 191 mm x 52 mm 9 8...

Page 45: ...nvironmental Conditions Table 4 Environmental Conditions Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 80 C 4 F 176 F Humidity 5 85 10 3 Standards and Certifications Table 5 Stand...

Page 46: ...12V DC 2 GND 11 2 Ethernet Connector Table 7 Ethernet Connector see Figure 2 pos 6 Pin Signal Name LAN1 LAN2 RJ45 1 MX1 8 7 6 5 4 3 2 1 2 MX1 3 MX2 4 MX3 5 MX3 6 MX2 7 MX4 8 MX4 11 3 USB 3 1 Port Tabl...

Page 47: ...tor Type A Version 2 0 1 5V 2 Data 3 Data 4 GND 11 5 DP Connector Table 10 DP Connector see Figure 2 pos 2 Pin Signal Name DP Connector 1 Link0 2 GND 3 Link0 4 Link1 5 GND 6 Link1 7 Link2 8 GND 9 Link...

Page 48: ...r Table 11 DVI D Connector see Figure 2 pos 3 Pin Signal Name DVI D Connector 1 Data2 2 Data2 3 GND 4 NC 5 NC 6 DDC_CLK 7 DDC_DATA 8 NC 9 Data1 10 Data1 11 GND 12 NC 13 NC 14 5V 15 GND 16 Hot plug det...

Page 49: ...DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 11 8 Line In Connector Table 13 Line In Connector see Figure 2 pos 4 Pin Signal Name Line in Connector Corresponding Audio Jack Plug Tip Line In_L Ring Line In_R Slee...

Page 50: ...ctor see Figure 2 pos 10 Pin Signal Name PS 2 Keyboard 6 pin Mini DIN Connector 1 KBD Data 2 NC 3 GND 4 5V 5 KBD CLK 6 Keyboard On 11 11 PS 2 Mouse Connector Table 16 PS 2 Mouse Connector see Figure 2...

Page 51: ...it until the first characters appear on the screen POST messages or splash screen 3 Press the F2 key 4 If the uEFI BIOS is password protected a request for password will appear Enter either the User P...

Page 52: ...em Specific Help window providing an explanation of the respective function 12 2 1 Main Setup Menu Upon entering the uEFI BIOS Setup program the Main Setup menu is displayed This screen lists the Main...

Page 53: ...Language English F1 General Help F2 Previous Values Access Level Administrator F3 Optimized Defaults F4 Save Exit Keyboard Layout English ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrend...

Page 54: ...A7 4E8B A86B 574701F488E3 Memory RC Version 0 7 1 100 ME Version 12 0 35 1427 PCH Information Name CNL PCH H PCH SKU Q370 Stepping B0 Network Controller Details LAN 2 MAC Address 4C 52 62 B1 3B 99 LAN...

Page 55: ...Software License Information This system board contains Open Source Software Select Screen For license details please visit the following web site Select Item Enter Select http support ts fujitsu com...

Page 56: ...tings CPU Configuration Drive Configuration SMART Settings Trusted Computing USB Configuration System Management LVDS Configuration Embedded Display Port Configuration Super IO Configuration Serial Po...

Page 57: ...ing USB Configuration System Management LVDS Configuration Embedded Display Port Configuration Select Screen Super IO Configuration Select Item Serial Port Console Redirection Enter Select AMT Configu...

Page 58: ...Select Item Enter Select Audio Configuration Change Opt Azalia HD Audio Enabled F1 General Help F2 Previous Values Mini PCIe WLAN Enabled F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271...

Page 59: ...Description Terms of use Decline Accept Please accept the terms of use to activate this feature The terms of use can be found in the BIOS manual or online at tou ts fujitsu com Remember By using this...

Page 60: ...evice to Generate PERR SERR Generation Disabled Enabled Enables or Disables PCI Device to Generate SERR PCI Express Slot 1 Disabled Enabled Auto Enables or Disables the PCI Express Slot Slot 1 Link Sp...

Page 61: ...VMM can utilize the additional hardware capabilities provided by Vanderpool Technology VT d Disabled Enabled Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O...

Page 62: ...t Screen SATA Port 2 Not Installed Select Item Port 2 Enabled Enter Select External SATA Disabled Change Opt Hot Plug Disabled F1 General Help SATA Port 3 Not Installed F2 Previous Values Port 3 Enabl...

Page 63: ...s Boot Save Exit SMART Settings SMART Self Test Enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 12...

Page 64: ...PM 2 0 Device Found F1 General Help Firmware Version 7 85 F2 Previous Values Vendor IFX F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc These ite...

Page 65: ...General Help USB Port Security F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Feature Option Description USB 3 1 Gen 2 speed...

Page 66: ...nable front and internal ports Enable rear and internal ports Enable internal ports only Enable used ports Configures how USB ports are enabled Enable all ports All USB ports are enabled Disable all p...

Page 67: ...Opt F1 General Help VCC 3 3V 3402 mV F2 Previous Values 3 3V AUX 3402 mV F3 Optimized Defaults V_IN 12V 12163 mV F4 Save Exit VBAT 3 0V 2717 mV ESC Exit Version 2 20 1271 Copyright C 2019 American Meg...

Page 68: ...e Option Description LVDS Support Disabled Enabled Enable disable LVDS Support Non EDID Support Disabled Enabled Always set to Enable for LVDS panel w o DDC LVDS Panel Config Select 800 x 600 1024 x 7...

Page 69: ...SBOX 7210 User Guide Rev 1 0 www kontron com 69 Feature Option Description Enabled LVDS is always set to dual channel mode...

Page 70: ...ions for the embedded Display Port eDP Set Brightness for the Embedded Display Port 128 Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Sa...

Page 71: ...Serial Port 1 Configuration BIOS SETUP UTILITY Main Advanced Security Power Event Logs Boot Save Exit Super Port 1 Configuration Serial Port Enabled Select Screen Device Settings IO 3F8h IRQ 4 Select...

Page 72: ...r Select Change Settings Auto Change Opt Serial Port Mode Selection F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrend...

Page 73: ...ious Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc This item appears only when selecting RS 485 Half Duplex or RS 485 422 Full Duplex fo...

Page 74: ...Disabled Select Item Console Redirection Settings Enter Select Change Opt COM2 Pci Bus0 Dev0 Func0 Disabled F1 General Help Console Redirection Port Is Disabled F2 Previous Values F3 Optimized Defaul...

Page 75: ...port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Data Bits 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with t...

Page 76: ...inals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x31 Disabled Enabled Enables or disables extended terminal resolution...

Page 77: ...e Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc These items are activated only when enabling Intel AMT Feature Option Description Intel AMT Disabled Enabled Enable Disable I...

Page 78: ...General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc These items appear only when enabling Network Stack Feature Optio...

Page 79: ...are activated only when selecting Auto or Enabled for Internal Graphics Feature Option Description Primary Display Auto Internal Graphics PCI Express for Graphics PEG PCI Express Select which graphics...

Page 80: ...Intel I210 Gigabit Network Connection Select Screen Chip Type Intel i210 Select Item PCI Device ID 1533 Enter Select PCI Address 02 00 00 Change Opt F1 General Help Link Status Disconnected F2 Previou...

Page 81: ...ious Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Feature Option Description Link Speed Auto Negotiated 10 Mbps Half 10 Mbps Full 100 M...

Page 82: ...FORMATION Select Item UEFI Driver Intel Gigabit 0 0 18 Enter Select Adapter PBA FFFFFF 0FF Change Opt Chip Type Intel PCH CNP F1 General Help PCI Device ID 15BB F2 Previous Values PCI Address 00 1F 06...

Page 83: ...elect Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc Feature Optio...

Page 84: ...a power on password and must be entered to boot or enter Setup In Setup the User will have USER rights The password length must be in the following range Minimum length 3 Maximum length 32 Minimum Us...

Page 85: ...TRICTED Enabled Windows Update WU and FUJITSU tools can change update the System firmware version Restricted only FUJITSU tools can change update the System firmware version Windows Update WU is block...

Page 86: ...eral Help Secure Boot Mode Standard F2 Previous Values F3 Optimized Defaults Key Management F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc This sub menu is activated...

Page 87: ...ult Secure Boot keys after the platform reset and while the System is in Setup mode Enroll all Factory Default Keys Yes No Force System to User Mode Install factory default Secure Boot key databases S...

Page 88: ...SBOX 7210 User Guide Rev 1 0 www kontron com 88 Feature Option Description Authorized TimeStamps Set New Key Append Key OsRecovery Signatures Set New Key Append Key...

Page 89: ...a record of all passwords in a safe place Forgotten passwords results in being locked out of the system If the system cannot be booted because the User Password or the Supervisor Password are not know...

Page 90: ...bled Wake Up Timer Disabled Hour 0 Minute 0 Second 0 Wake Up Mode Daily Sunday 1 Disabled Monday 1 Disabled Tuesday 1 Disabled Wednesday 1 Disabled Thursday 1 Disabled Friday 1 Disabled Saturday 1 Dis...

Page 91: ...d Allows the system to be switched on via a LAN wakeup Wake On LAN boot Boot Sequence Force LAN Boot Boot Sequence Use Boot Sequence order after Wake On LAN Force LAN Boot Force LAN boot after Wake On...

Page 92: ...SBOX 7210 User Guide Rev 1 0 www kontron com 92 Feature Option Description CPU TDP Limit Disabled Enabled Enable CPU TDP limitation CPU TDP Limit Value Value input Define the maximum CPU TDP value W...

Page 93: ...ange Smbios Event Log Settings View Smbios Event Log Figure 50 BIOS Event Logs Setup Menu BIOS SETUP UTILITY Main Advanced Security Power Event Logs Boot Save Exit Change Smbios Event Log Settings Vie...

Page 94: ...g boot Erase Event Log No Yes Next reset Yes Every reset Choose options for erasing Smbios Event Log Erasing is done prior to any logging activation during reset When Log is Full Do Nothing Erase Imme...

Page 95: ...the keyboard NumLock state Quiet Boot Disabled Enabled Enables or disables Quiet Boot option Logo Resolution Default Resolution Native Resolution Static Resolution Configures the screen resolution De...

Page 96: ...n Description Disabled The Boot menu cannot be invoked Boot Removable Media Disabled Enabled This option enables disables support for booting to removable devices such as USB flash drives Boot Option...

Page 97: ...ter Select Change Opt Boot Override F1 General Help Windows Boot Manager P1 SanDisk SSD U110 128GB F2 Previous Values Diagnostic Program F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 C...

Page 98: ...ive HDMI High Definition Multimedia Interface LAN Local Area Network LED Light Emitting Device LVDS Low Voltage Differential Signaling ME F W Management Engine Firmware mPCIe mini Peripheral Component...

Page 99: ...solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accelerate...

Reviews: