General Safety Instructions 

Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety 
and to ensure to apply in accordance with intended regulations. If the following general safety instructions are not 
observed, it could lead to injuries to the operator and/or damage of the product; in cases of non-observance of the 
instructions Kontron Europe is exempt from accident liability, this also applies during the warranty period. 

The product has been built and tested according to the basic safety requirements for low voltage (LVD) applications 
and has left the manufacturer in safety-related, flawless condition. To maintain this condition and to also ensure safe 
operation, the operator must not only observe the correct operating conditions for the product but also the following 
general safety instructions:  

 

The product must be used as specified in the product documentation, in which the instructions for safety for the 
product and for the operator are described. These contain guidelines for setting up, installation and assembly, 
maintenance, transport or storage. 

 

The on-site electrical installation must meet the requirements of the country's specific local regulations. 

 

If a power cable comes with the product, only this cable should be used. Do not use an extension cable to connect 
the product. 

 

To guarantee that sufficient air circulation is available to cool the product, please ensure that the ventilation 
openings are not covered or blocked. If a filter mat is provided, this should be cleaned regularly. Do not place the 
product close to heat sources or damp places. Make sure the product is well ventilated. 

 

Only connect the product to an external power supply providing the voltage type (AC or DC) and the input power 
(max. current) specified on the Kontron Product Label and meeting the requirements of the Limited Power Source 
(LPS) and Power Source (PS2) of UL/IEC 62368-1 . 

 

Only products or parts that meet the requirements for Power Source (PS1) of UL/IEC 62368-1 may be connected 
to the product’s available interfaces (I/O). 

 

Before opening the product, make sure that the product is disconnected from the mains.  

 

Switching off the product by its power button does not disconnect it from the mains. Complete disconnection is 
only possible if the power cable is removed from the wall plug or from the product. Ensure that there is free and 
easy access to enable disconnection. 

 

The product may only be opened for the insertion or removal of add-on cards (depending on the configuration of 
the product). This may only be carried out by qualified operators.  

 

If extensions are being carried out, the following must be observed:   

 

all effective legal regulations and all technical data are adhered to 

 

the power consumption of any add-on card does not exceed the specified limitations  

 

the current consumption of the product does not exceed the value stated on the product label.   

 

Only original accessories that have been approved by Kontron Europe can be used.  

 

Please note: safe operation is no longer possible when any of the following applies: 

 

the product has visible damages or 

 

the product is no longer functioning 
In this case the product must be switched off and it must be ensured that the product can no longer be 
operated. 

 

Handling and operation of the product is permitted only for trained personnel within a work place that is access 
controlled. 

 

CAUTION:  Risk of explosion if the battery is replaced incorrectly (short-circuited, reverse-poled, wrong battery 
type). Dispose of used batteries according to the manufacturer’s instructions. 

 

This product is not suitable for use in locations where children are likely to be present 

 

Additional Safety Instructions for DC Power Supply Circuits 

 

To guarantee safe operation, please observe that:  

 

the external DC power supply must meet the criteria for LPS and PS2 (UL/IEC 62368-1)  

 

no cables or parts without insulation in electrical circuits with dangerous voltage or power should be 
touched directly or indirectly  

 

a reliable protective earthing connection is provided  

Summary of Contents for kontron KSwitch D3

Page 1: ...USER GUIDE www kontron com KSwitch D3 Unmanaged Fast Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1422...

Page 2: ...KSwitch D3 Unmanaged Fast Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Page 3: ...rranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description...

Page 4: ...pplications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for com...

Page 5: ...tacts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kontron ex...

Page 6: ...indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title informs that the electronic boards and their co...

Page 7: ...of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables which pr...

Page 8: ...ircuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when replacing the...

Page 9: ...onents used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE Compl...

Page 10: ...ackaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 15 3 5 Product Identification Type Label 17 4 Features 18 4 1 Faceplate Features 19 4 1 1 RJ45 Copper Ethernet Ports 19 4 1 2 SFP...

Page 11: ...le 8 Certification Compliance 32 Table 9 Mechanical Specification 32 Table 10 Electrical Specification 34 Table 11 List of Acronyms 38 List of Figures Figure 1 KSwitch Type Label 17 Figure 2 KSwitch D...

Page 12: ...n of this user guide visit Kontron s KSwitch Industrial Ethernet Switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switch s features and...

Page 13: ...wer Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfaces I...

Page 14: ...roken fiber or an energized fiber 2 2 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry Therefore proper packaging and...

Page 15: ...ant information for handling the switch 5 Check the contents for visible shipping damage If you notice any shipping damage or inconsistencies between the contents and the original order contact Kontro...

Page 16: ...m 1310nm wide operating Temp 40 85 EN SFP F S030 T 100 Megabit SFP Modules 100BaseF X ps single mode transceiver 30km 1310nm wide operating Temp 40 85 EN SFP F S060 T 100 Megabit SFP Modules 100BaseF...

Page 17: ...on com 17 3 5 Product Identification Type Label Figure 1 KSwitch Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production date...

Page 18: ...net switch with up to 24 fast Ethernet ports providing easy to use plug n play connectivity Copper and fiber optics ports are available Figure 2 KSwitch D3 UF Unmanaged Fast Ethernet Switch Key featur...

Page 19: ...ir or STP Shielded Twisted Pair Ethernet cables The switch supports eight 10 100 Mbps copper RJ45 Ethernet ports and up to two 100 Base fiber SFP slots on the 10 port variant and 16 copper 10 100 Mbps...

Page 20: ...s to the receive RX port of the other device and the receive RX port of the switch connects to the transmit TX port of the other device Figure 4 SFP Ports 10 port Laser To avoid ocular exposure and a...

Page 21: ...larm indicator LEDs Figure 5 Indicator LED 10 port and 16 port Table 4 Indicator LEDs LED Name Indicator Color Condition P1 P2 On Green P1 P2 power line has power Off P1 P2 power line disconnect or do...

Page 22: ...itch supports fault alarm notification for power To check for correct operation refer to the LED indicators P1 and P2 on the faceplate Figure 6 Power Contacts 16 port 1 P1 contacts 2 P2 contacts When...

Page 23: ...cts on the DC terminal block Figure 7 Alarm Relay Contacts 16 port 1 Alarm System 2 Extra Power System When attaching wires to the DC terminal block s contacts consider DC terminal block pitch 5 08 mm...

Page 24: ...clamp screws to prevent the wires from loosening The switch supports fault alarm notification for power To check for correct operation refer the LED indicators P1 and P2 on the faceplate Figure 9 Pow...

Page 25: ...circuit The alarm relay output is Normal Close To activate the alarm relay insert the wires into the corresponding contacts on the DC terminal block Figure 10 Alarm Relay Contacts 10 port 1 Alarm syst...

Page 26: ...26 4 2 3 Ground Connector 10 port The switch must be grounded properly using the ground connector for optimum system performance Figure 11 Ground Connector 10 port Ground properly using a ground that...

Page 27: ...ing holes on the top and bottom 10 port and left and right 16 port on the rear side enable installation of the wall mount plates For mounting information see Chapter 5 Mounting Figure 12 Rear Side Vie...

Page 28: ...llowing 1 Fasten the DIN Rail clip to the switch in the upper position Figure 13 for the required mount orientation with the three screws length 5 mm size M3 provided Figure 13 DIN Rail Clip 2 Hook th...

Page 29: ...nt plate s mounting holes to the top of the wall mount plate is 27 mm To install the wall mount plates supplied in the Wall Mount Kit perform the following 1 Make sure the mounting surface is clean an...

Page 30: ...ound cable to the ground connector and ensure that the installation sites ground meets the grounding requirements specified in your local national and international region If access to power is restri...

Page 31: ...Ports Speed Up to 24x 10 100 Mbps MDI MDIX Auto crossover Support straight or cross wired cables Auto negotiation Duplex 10 100 1000 Mbps speed auto negotiation full half duplex Ethernet Port Protect...

Page 32: ...EMC EN 61000 6 3 Class B EN 61000 6 4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rules and regulations and ANSI C63 4 2014...

Page 33: ...KSwitch D3 Unmanaged Fast Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 33 Figure 16 Mechanical Dimensions 16 port...

Page 34: ...e grounding requirements specified in your local national and international region The DC power supply must be connected to a well fused power source To protect the switch and any connected peripheral...

Page 35: ...tenance or repair on the switch may only be carried out by qualified personnel authorized by Kontron Return the switch to Kontron for maintenance and repair see Chapter 9 1 Returning Defective Merchan...

Page 36: ...period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA Request sheet...

Page 37: ...utory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warning la...

Page 38: ...LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI Multi...

Page 39: ...dustry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a v...

Reviews: