ENGLISH 
 
TD - SILENT SERIES 
 

The  TD  -  SILENT  mixed  flow  range  of  in-line  duct  exhaust  fans  have  been  manufactured  in  accordance  with  the 
rigorous standards of production as defined by the International Quality Standards ISO 9001. All the components have 
been checked and tested at the end of the manufacturing process. 
 
We recommend that you check the following after receiving this product: 
 

1. The correct size has been received 
2. The correct model has been received 
3. The details on the rating label correspond to the electrical supply: voltage, frequency etc. 
 

Remove the unit from packaging and inspect for shipping damage within 15 days of receipt. If the product is found to 
be damaged, immediately contact your local authorized supplier. DO NOT OPERATE THE UNIT IF DAMAGED. 
 
These  instructions  should  be  considered  as  a  supplement  to  EPA  standard  practices,  as  well  as  all  state  and  local 
building code regulations. 
 

ENVIRONMENT 
 

The  TD-SILENT  series  of  fans  are  suitable  for  operation  within  indoor  environments  only.  The  TD-Silent  units  are 
suitable  for  the  exhaust  or  supply  of  both  conditioned  and  un-conditioned  airstreams  within  the  temperature  ranges 
(inclusive of duct airstream’s temperature) of -40°C up to +40°C for models TD-100XS; and -40°C up to +60°C 
for models TD-150S, -200S.  
 

INSTALLATION 
 
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: 

 

(a)  Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have  any  questions  contact  the 

manufacturer.

 

(b)  Before  servicing  or  cleaning  the  unit,  switch  the  power  off  at  the  service  panel  and  lock  the  service 

disconnecting  means  to  prevent  power  from  being  switched  on  accidentally.  When  the  service 
disconnecting means cannot be locked; securely fasten a prominent warning device such as a tag to the 
service panel. 

(c)   Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable 

codes & standards including fire rated construction. 

(d)  Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel 

burning  equipment  to  prevent  back  drafting.  Follow  the  heating  equipment  manufacturers  guideline  and 
safety  standards  such  as  those  published  by  the  National  Fire  Protection  Association  (NFPA)  and  the 
American Society For Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code 
authorities. 

(e)  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

 

(f)   Ducted fans must always be vented to the outdoors. 
(g)  If this unit is to be installed over a tub or a shower, it must be marked as appropriate for the application and 

connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 

(h)  Never place a switch where it can be reached from a tub or shower.

 

(i)  CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials 

And Vapors.

 

(j)  CAUTION:  MOUNT  WITH  THE  LOWEST  MOVING  PARTS  AT  LEAST  2.4  M  (8  FEET)  ABOVE  THE 

FLOOR OR GRADE LEVEL. 

(k)  All the units are suitable for use with solid state speed control 
 

The TD - SILENT series can be mounted in any orientation, horizontal or vertical, and is suitable for numerous types of 
applications. See 

Figure (1)

. Illustration of some typical applications. 

If the installation is made to rigid or flexible ducting, then we would recommend the correct diameter ducting is used to 
couple to the fan flanges. If it is necessary to bend the duct at the discharge of the fan, then the bend radius should be 
as large as possible. 
 

Summary of Contents for TD Series

Page 1: ...N LINEA VENTILATEURS HELICOCENTRIFUGES EN LIGNE Models TD 100XS TD 150S TD 200S INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS ...

Page 2: ...eel assembly must first be removed Unlock the two flanges around the casing and remove Desmontar el cuerpo motor abriendo las dos bridas que lo fijan al pie soporte Pour installer les modèles TD SILENT démonter le corps moteur puis ouvrir des deux brides qui le fixent au pied support 2 Secure the mounting bracket fan flange assembly to a fixed structure Fijar el pie soporte a la pared o techo Fixe...

Page 3: ...r de velocidad Moteur avec régulateur de vitesse IMPORTANT ALL TD SILENT PRODUCTS INCORPORATE TWO SPEED 120VAC 60Hz MOTORS THE LIVE SUPPLY MUST ONLY BE MADE TO TERMINAL HI OR LO CONNECTION NOT TOGETHER IMPORTANTE TODOS LOS TD SILENT INCORPORAN UN MOTOR 120V 60Hz DE DOS VELOCIDADES LA FASE TIENE QUE CONECTARSE ÚNICAMENTE AL TERMINAL HI O LO NO A LOS DOS A LA VEZ IMPORTANT TOUS LES TD SILENT INCORPO...

Page 4: ...identally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes standards including fire rated construction d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney...

Page 5: ...at the TD SILENT series exhaust fan will be free from defective materials and workmanship for the period of 5 years from the date of original purchase In the event that we find any part is defective the product will be repaired or in the Company s discretion replaced without charge provided that the product has been installed in accordance with the enclosed instructions and all applicable EPA Stan...

Reviews: